Laserfiche WebLink
Pace Analytical Services,Inc. <br /> ® 2795 Second Street-Suite 300 <br /> ace Analytical Davis.CA 95618 <br /> wwwpacela0.s.crom (530)2974800 <br /> QUALIFIERS • <br /> Project: Parcel 2A(2063971211321 &P66 <br /> Pace Project No.: 1259724 <br /> DEFINITIONS <br /> OF-Dilution Factor,if reported,represents the factor applied to the reported data due to dilution of the sample aliquot. <br /> ND-Not Detected at or above adjusted reporting limit. <br /> J-Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. <br /> MDL-Adjusted Method Detection Limit. <br /> PQL-Practical Quantitation Limit. <br /> RL-Reporting Limit. <br /> S-Surrogate <br /> 1,2-Diphenylhydrazine decomposes to and cannot be separated from Azobenzene using Method 8270.The result for each analyte is <br /> a combined concentration. <br /> Consistent with EPA guidelines,unrounded data are displayed and have been used to calculate%recovery and RPD values. <br /> LCS(D)-Laboratory Control Sample(Duplicate) <br /> MS(D)-Matrix Spike(Duplicate) <br /> DUP-Sample Duplicate <br /> RPD-Relative Percent Difference <br /> NC-Not Calculable. <br /> SG-Silica Gel-Clean-Up <br /> U-Indicates the compound was analyzed for,but not detected. <br /> N-Nitrosodiphenylamine decomposes and cannot be separated from Diphenylamine using Method 8270. The result reported for <br /> each analyte is a combined concentration. • <br /> Pace Analytical is TNI accredited.Contact your Pace PM for the current list of accredited analytes. <br /> TNI-The NELAC Institute. <br /> LABORATORIES <br /> PASI-DAV Pace Analytical Services-Davis <br /> ANALYTE QUALIFIERS <br /> IV Discrete peaks present,atypical for Hydraulic oil. <br /> 2V Hydrocarbons are lower boiling than typical hydraulic oil. <br /> 3V Hydrocarbons are lower than typical hydraulic oil. <br /> 4V Lower boiling than typical hydraulic oil. <br /> B Analyte was detected in the associated method blank. <br /> DE Discrete peaks present,atypical for Diesel Fuel. <br /> DM Higher boiling hydrocarbons present,atypical for Diesel Fuel. <br /> M3 Matrix spike recovery was outside laboratory control limits due to matrix interferences. <br /> P8 Analyte was detected in the method blank.All associated samples had concentrations of at least ten times greater than <br /> the blank or were below the reporting limit. <br /> S5 Surrogate recovery outside control limits due to matrix interferences(not confirmed by re-analysis). <br /> • <br /> REPORT OF LABORATORY ANALYSIS <br /> This report shall not be reproduced,except In full, <br /> Date:01/28/2016 07:00 PM without the written consent of Pace Analytical Services,Inc.. Page 40 of 49 <br />