My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PESCADERO
>
800
>
2200 - Hazardous Waste Program
>
PR0514340
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/27/2020 1:07:41 PM
Creation date
6/25/2020 11:04:34 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0514340
PE
2227
FACILITY_ID
FA0010472
FACILITY_NAME
Penske Truck Leasing Co., LP
STREET_NUMBER
800
Direction
E
STREET_NAME
PESCADERO
STREET_TYPE
Ave
City
Tracy
Zip
95304
CURRENT_STATUS
01
SITE_LOCATION
800 E Pescadero Ave
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2002 Page I of 1 <br /> 6 . PIPING SUMP TESTING <br /> Test Method Developed By : Tank Manufacturer Industry Standard Professional Engineer <br /> r+ Other (Specify) <br /> Test Method Used By : 17� Pressure F Vacuum F Hydrostatic <br /> Other (Specify) <br /> Test Equipment Used : LAKE TEST Equipment Resolution : 0.0625 in. <br /> Tank Used Antifreeze <br /> WASTE ANTIFREEZ - <br /> Manway Sump <br /> Sump Diameter/Dimensions : 30 in, in. in. in. <br /> Sump Depth: 42. 00 in. in. in. in. <br /> Sump Material : Polyethylene <br /> Height from Tank Top to Top of 0.00 <br /> Highest Piping Penetration : <br /> Height from Tank Top to Lowest 0.00 <br /> Electrical Penetration : <br /> Condition of sump prior to testing : clean <br /> Portion of Sump Tested ' <br /> Does turbine shut down when <br /> sump sensor detects liquid ( both r Yes r No (* NA r Yes r Nor NA r Yes r No r NA r Yes r No r NA <br /> product and water)? * <br /> Turbine shutdown response time sec sec sec sec <br /> Is system programmed for fail-safe r Yes r Nor* NA r Yes C No r NA r Yes r No r NA r Yes r No r NA <br /> shutdown? * "! <br /> Was fail-safe verified to be r Yes r No Co NA r Yes r No r NA C Yes r No r NA r Yes C No r NA <br /> operational ?* <br /> Wait time between applying <br /> pressure/vacuum/water and starting 15 nun min min min <br /> test <br /> Test Start Time : 17: 12:00 <br /> Initial Reading (RI ): 36.00000 in. <br /> Test End Time: 19: 12:00 <br /> Final Reading (RF): 36.00000 in. <br /> Test Duration : 2 hr <br /> Change in Reading (RF-RI ) : 0.00000 in. <br /> Pass/Fail Threshold or Criteria: +/- 0. 12500 +/- <br /> Test Result: Pass ' <br /> Was sensor removed for testing? C Yes r Nor NA r Yes r No r NA r Yes r Nor NA r Yes r Nor NA <br /> Was sensor properly replaced and r Yes r Nor NA r Yes r Nor NA r Yes C Nor NA r Yes r No r NA <br /> verified functional after testing? <br /> Comments - (include information on repairs made prior to testing, and recommended folloiv-up for failed tests) <br /> Test on secondary drum on waste oil antifreeze. Primary drum was removed for the test. Hydro level covered to the top of the drum . <br /> ' If the entire depth of the sump is not tested, specify how much was tested . If the answer to any of the questions indicated with an <br /> asterisk ( * ) is "NO " or "NA" , the entire sump must be tested. <br /> W0 : 6703842 <br />