FLOOR SINK NOTE <br /> FLOOR SINKS SHALL BE HALF IN AND HALF OUT <br /> AND WILL NOT BE ALLOWED IN CUPBOARDS. <br /> PLUMBINGWASTE NOTES ©2020 STARBUCKS COFFEE COMPANY <br /> STARBVCKS° <br /> A SEE SHEET P-0004 FOR FIXTURE SCHEDULES. 2401 UTAH AVENUE SOUTH <br /> PLUMBING CONTRACTOR IS RESPONSIBLE FOR SITE INVESTIGATION PRIOR SEATTLE, WASHINGTON 98134 <br /> B TO START OF ANY WORK TO IDENTIFY FULL SCOPE OF WORK. (206) 318-1575 <br /> C COORDINATE WITH ELECTRICAL CONTRACTOR FOR POWER CONNECTIONS TO THESE DRAWINGS AND THE PROJECT MANUAL <br /> ALL PLUMBING EQUIPMENT. ARE CONFIDENTIAL AND SHALL REMAIN THE <br /> SOLE PROPERTY OF STARBUCKS <br /> D REFER TO ARCHITECTURAL DETAILS FOR PLUMBING FITTINGS LOCATED CORPORATION, WHICH IS THE OWNER OF THE <br /> WITHIN CASEWORK. COPYRIGHT IN THIS WORK. THEY SHALL NOT <br /> CONTRACTOR SHALL DETERMINE THE EXACT LOCATIONS,SIZES AND BE REPRODUCED(IN WHOLE OR IN PART), <br /> DIRECTION OF FLOW OF EXISTING WASTE AND VENT SYSTEMS PRIOR TO SHARED WITH THIRD PARTIES OR USED IN ANY <br /> E START OF WORK AND MAKE ADJUSTMENT IN THE PLUMBING WASTE LAY-OUT MANNER ON OTHER PROJECTS OR <br /> SHOWN ON THE DRAWING TO SUIT FIELD CONDITIONS. EXTENSIONS TO THIS PROJECT WITHOUT THE <br /> PRIOR WRITTEN CONSENT OF STARBUCKS <br /> CORPORATION. THESE DRAWINGS AND <br /> CONTRACTOR SHALL REPORT TO STARBUCKS CONSTRUCTION MANAGER ANY <br /> LF F DISCREPANCY BETWEEN THESE DRAWINGS AND FILED CONDITIONS PRIOR TO SPECIFICATIONS ARE INTENDED TO EXPRESS <br /> COMMENCING WITH ANY WORK. DESIGN INTENT FOR A PROTOTYPICAL <br /> STARBUCKS STORE (WHICH IS SUBJECT TO <br /> SAWCUT(E)CONCRETE FLOOR SLAB AS NEEDED TO INSTALL NEW PIPING. CHANGE AT ANYTIME)AND DO NOT REFLECT <br /> G AFTER PIPING INSTALLATION IS COMPLETE BRING THE AFFECTED FLOOR ACTUAL SITE CONDITIONS. NEITHER PARTY <br /> SLAB TO ITS ORIGINAL CONDITION. SHALL HAVE ANY OBLIGATION NOR LIABILITY TO <br /> THE OTHER(EXCEPT STATED ABOVE)UNTIL A <br /> BEFORE COMMENCING WITH ANY WORK CONTRACTOR SHALL COORDINATE WRITTEN AGREEMENT IS FULLY EXECUTED BY <br /> H AND VERIFY WITH STARBUCKS CONSTRUCTION MANAGER FOR ALL MODELS, I BOTH PARTIES. <br /> ■ SCOPE AND OPERATIONAL REQUIREMENT OF ALL PLUMBING FIXTURES <br /> PRESENTED IN THESE DOCUMENTS. STARBUCKS TEMPLATE VERSION: 12020.10.23 <br /> I ALL INDIRECT DRAIN LINES MUST BE OF RIGID STRUCTURE.FLEXIBLE <br /> INDIRECT DRAIN LINES ARE NOT ACCEPTABLE. <br /> 3 10549 J FLOOR SINKS SHALL BE HALF IN AND HALF OUT AND WILL NOT BE ALLOWED IN architecture <br /> interiors <br /> WCO CUPBOARDS. and <br /> ( /2"V K PROVIDE X-RAY OF EXISTING BEAMS BEFORE ANY NEW PENETRATION AND <br /> ® t� <br /> PIPE ROUTING TROUGH THE BEAM. 858 Wilshire Blvd #200 T: 323.954.8996 <br /> (N)2"SS <br /> IN WALL „� ALL NEW CONNECTIONS TO EXISTING INFRASTRUCTURE SHOWN ON THESE Los Angeles, CA 90036 F: 323.954.8965 <br /> 110 �--� L DOCUMENTS SHALL BE VERIFIED IN THE FIELD PRIOR TO ANY INSTALLATION WWW.valerioinc.com * info@valerioinc.com <br /> 3 14688 WORK. UPON FIELD INSPECTION,CONTRACTOR HAS OPTION OF REUSING <br /> WCO d► © SECTIONS OF EXISTING SYSTEMS AND PIPING AS HE FINDS APPROPRIATE. <br /> INDIRECT DRAIN PIPE SIZES SHOWN ON SCHEDULE ON SHEET P-0002 ARE FOR :••RpFESS/•• <br /> M REFERENCE ONLY.EXACT SIZES AND ROUTING OF INDIRECT DRAIN PIPING ACIES ��Q N R Nq�••• <br /> 20010 7 :��o�P F�,Fy•'. <br /> SHALL BE DETERMINED IN THE FIELD. � 9 i <br /> ENGINEERING <br /> �0 d N PIPING AND CONDUITS OF ALL TYPES(ELECTRICAL,WATER AND DRAIN LINES) 400 N McCarthy Blvd. E0. <br /> MUST BE CONCEALED WITHIN WALLS,FLOORS AND CEILINGS. Suite 250,Milpitas,CA 95035 •�'� <br /> O WCO 3 `� - \ fx:(08)522-5260 ••h:(408)522-5255 • F�OF CAI F�,�?P•• <br /> 9 E FS �� <br /> 9 EFS info@acies.net ••••.• <br /> SHEET NOTES Copyright©2021 <br /> CE: A <br /> 1 = ll <br /> 19742 4L CONNECT TO EXISTING SANITARY SEWER PIPING AND VENT PIPING.VERIFY <br /> O IN THE FIELD EXACT LOCATION,SIZE AND INVERT ELEVATION OF EXISTING <br /> 8 E F VE 1A <br /> CONNECTING LINE. <br /> OPROVIDE NEW 3"SANITARY SEWER AND 2"VENT UP. <br /> 5 277TOM <br /> O PROVIDE NEW 2"SANITARY SEWER AND 1-112"VENT UP. <br /> 9 EFS El <br /> 6 19278 EXTEND INDIRECT DRAIN PIPING FROM ESPRESSO MACHINE TO FLOOR SINK. <br /> EXTEND INDIRECT DRAIN PIPING FROM WORK/RINSE SINK TO FLOOR SINK. <br /> 5 1 77 — II 19742 4 [�6 EXTEND INDIRECT DRAIN PIPING FROM ICE BIN TO FLOOR SINK. <br /> J EXTEND INDIRECT DRAIN PIPING FROM NITRO DISPENSING SYSTEM TOLO <br /> r z <br /> ® (N)3"SS i O FLOOR SINK. LN <br /> 0 0 10294 2 10726 O4 M 0 <br /> Q(E)FLOOR SINK I DRAIN TO BE REMOVED WITH ASSOCIATED PLUMBING <br /> 8 19278 (N)2"V 072 O PIPING.CAP WASTE AND VENT PIPING BELOW FLOOR AND IN CEILING AS U-1 <br /> Q U <br /> WCO 1 NEEDED.FILL IN THE HOLE AND PATCH THE FLOORING TO MATCH EXISTING J U z <br /> FINISHING. _ — <br /> (E)FLOOR SINK TO REMAIN.CONTRACTOR TO VERIFY IN THE FIELD ACTUAL W z z <br /> O LOCATION OF EXISTING FLOOR SINK AND TO ADJUST IF NEEDED. 2i — O <br /> z ~ Q O <br /> W = w N U <br /> o o � Q <br /> W W a C) (n <br /> STORE #: 9287 <br /> PROJECT #: 23544-077 <br /> ISSUE DATE: 03/12/2021 <br /> SR. DESIGN MANAGER: JESSICA RAMOS <br /> DESIGN MANAGER: <br /> CHECKED BY: <br /> Revision Schedule <br /> Rev Date By Description <br /> 03/12/21 ACIES PERMIT SET <br /> SHEET TITLE: <br /> PLUMBING WASTE <br /> AND VENT PLAN <br /> Plumbing waste and vent plan SCALE: 1/4"= 1'-0" <br /> SHEET NUMBER: <br /> Scale: 114" = 1'-0" P- 1103 <br />