Laserfiche WebLink
2020 STARBUCKS COFFEE COMPANY <br /> Q <br /> STARBUCKS' <br /> 2401 UTAH AVENUE SOUTH <br /> SEATTLE, WASHINGTON 98134 <br /> (206) 318-1575 <br /> A THESE DRAWINGS AND THE PROJECT MANUAL <br /> 5 G ARE CONFIDENTIAL AND SHALL REMAIN THE <br /> 1 7 SOLE PROPERTY OF STARBUCKS <br /> -- 10 -- 2 >*Q+ *Q+ CORPORATION, WHICH IS THE OWNER OF THE <br /> . 1 - Q - COPYRIGHT IN THIS WORK. THEY SHALL NOT <br /> _ BE REPRODUCED (IN WHOLE OR IN PART), <br /> SHARED WITH THIRD PARTIES OR USED IN ANY <br /> MANNER ON OTHER PROJECTS OR <br /> — . <br /> EXTENSIONS TO THIS PROJECT WITHOUT THE <br /> PRIOR WRITTEN CONSENT OF STARBUCKS <br /> . CORPORATION. THESE DRAWINGS AND <br /> i SPECIFICATIONS ARE INTENDED TO EXPRESS <br /> t > Q <br /> DESIGN INTENT FOR A PROTOTYPICAL <br /> STARBUCKS STORE (WHICH IS SUBJECT TO <br /> 06 CHANGE\� 8 9 CHANGE AT ANYTIME) AND DO NOT REFLECT <br /> - -k. ACTUAL SITE CONDITIONS. NEITHER PARTY <br /> _ > G SHALL HAVE ANY OBLIGATION NOR LIABILITY TO <br /> I �\ IIT THE OTHER (EXCEPT STATED ABOVE) UNTIL A <br /> 10 r7� <br /> WRITTEN AGREEMENT IS FULLY EXECUTED BY <br /> 4 14 <br /> 10 <br /> BOTH PARTIES. <br /> o X <br /> N <br /> N �� -x 6 STARBUCKS TEMPLATE VERSION: i2020.10.23 <br /> CD <br /> 2 - <br /> N <br /> architecture• <br /> p Q , • <br /> O • interiors <br /> N > : <br /> • • • <br /> U) <br /> O . - - - - - - <br /> •— 3 �r� � > _ _ G_ 858 Wilshire Blvd #200 T: 323.954.8996 <br /> 6 Q os Angeles, CA 90036 F: 323.954.8965 <br /> ww.valerioinc.com * info@valerioinc.com <br /> � Q <br /> A C <br /> N U z LIC.NO. <br /> r i C 24228 y <br /> U <br /> EXPIRES <br /> Q <br /> 9 OF CAL�O¢ <br /> U <br /> 0 <br /> rn <br /> r` <br /> N <br /> i <br /> U I 0 <br /> co <br /> O <br /> O <br /> O) <br /> N O O <br /> rr <br /> c� <br /> _LI Q <br /> 06 <br /> � � z <br /> 75 — � � � <br /> 4-1I 06 Q a) O <br /> LU TQC) <br /> UI J 0 � Uz <br /> X' � o —: 0 <br /> U) z Q Q <br /> T O <br /> r U 1 U C\1 <br /> 6 Lu o � � � � O Q <br /> MEANS OF EGRESS NOTES KEYED NOTES LEGEND W � o <br /> N <br /> STORE #: 9287 <br /> A. EVERY ROOM OR SPACE THAT IS ASSEMBLY OCCUPANCY SHALL HAVE THE D. TRUCTURAL ELEMENTS, FIXTURES OR FURNISHINGS SHALL NOT PROJECT G. EGRESS DOORS OR GATES SHALL BE OPENABLE FROM THE EGRESS SIDE 1. THRESHOLDS TO BE BARRIER FREE COMPLIANT PER ALL APPLICABLE CODES. RETAIL <br /> O OCCUPANT LOAD OF THE ROOM OR SPACE POSTED IN A CONSPICUOUS PLACE, HORIZONTALLY FROM EITHER SIDE MORE THAN 4 INCHES (100 MM) OVER WITHOUT THE USE OF A KEY, SPECIAL KNOWLEDGE OR EFFORT. DOOR PROJECT #: 23544-077 <br /> n NEAR THE MAIN EXIT ACCESS DOORWAY. POSTED SIGNS SHALL BE OF AN ANY WALKING SURFACE BETWEEN 27 INCHES (685 MM) AND 80 INCHES (2030 HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERATING DEVICES SHALL 2. BARRIER-FREE PATH OF TRAVEL. PREP ISSUE DATE: 03-12-21 <br /> N APPROVED LEGIBLE PERMANENT DESIGN AND SHALL BE MAINTAINED BY THE MM) ABOVE THE WALKING SURFACE. BE INSTALLED 34 INCHES (860 MM) TO 48 INCHES (1220 MM) ABOVE FINISHED <br /> OWNER AUTHORIZED AGENT. (1004.3) EXCEPTION: HANDRAILS SERVING STAIRS AND RAMPS ARE PERMITTED TO FLOOR. MANUALLY OPERATED FLUSH BOLTS OR SURFACE BOLTS ARE NOT 3. 30" (160 MM) X 48" (1220 MM) CLEAR FOR WHEELCHAIR ACCESS. DESIGN MANAGER: JESSICA RAMOS <br /> N PROTRUDE 4 1/2 INCHES (115 MM) FROM THE WALL. (1003.3.3) PERMITTED. THE UNLATCHING OF ANY DOOR OR LEAF SHALL NOT REQUIRE QUEUE LINE <br /> B. EGRESS SHALL NOT PASS THROUGH KITCHENS, STORAGE ROOMS, CLOSETS MORE THAN ONE OPERATION. (1008.1.9) 4. 60" (1525 MM) DIAMETER MINIMUM TURN RADIUS FOR WHEELCHAIR ACCESS. CHECKED BY: LILY JUMANAN <br /> 0 OR SIMILAR SPACES. (1014.2) E. THE PATH OF EGRESS TRAVEL EXITS AND WITHIN EXITS IN THIS BUILDING <br /> 0 SHALL BE IDENTIFIED BY EXIT SIGNS CONFORMING TO THE REQUIREMENTS H. LANDINGS SHALL BE PROVIDED ON EACH SIDE OF DOORS AND SUCH 5. 32" (815 MM) MINIMUM CLEAR AT RESTROOM DOOR. B.O.H. <br /> n C. PANIC AND FIRE EXIT HARDWARE, WHERE INSTALLED ON DOORS IN THIS OF SECTION 1011 AND AS NOTED BELOW: LANDING SHALL BE AT THE SAME ELEVATION ON EACH SIDE OF THE DOOR Revision Schedule <br /> BUILDING SHALL SATISFY THE FOLLOWING (1008.1.10): LANDINGS SHALL HAVE A WIDTH NOT LESS THAN THE WIDTH OF THE DOOR 6. POS TRANSACTION PLANE, CONDIMENT CART TOP AND HAND-OFF PLANE ARE CAFE SEATING <br /> 1) EXIT SIGNS SHALL BE READILY VISIBLE FROM ANY DIRECTION OF AND LENGTH MEASURED IN THE DIRECTION OF TRAVEL OF NOT LESS THAN 34 INCHES ABOVE THE FINISHED FLOOR FOR WHEELCHAIR ACCESSIBILITY. Rev Date By Description <br /> 1) THE ACTUATION PORTION OF THE RELEASING DEVICE SHALL EXTEND AT EGRESS TRAVEL. 44 INCHES (11120 MM). (1008.1.5, 1008.1.6) 02-26-21 WY CHECK SET <br /> LEAST ONE-HALF OF THE DOOR LEAF WIDTH. 7. PROVIDE BARRIER-FREE SIGNAGE AT ACCESSIBLE RESTROOMS PER ALL ------ PATH OF TRAVEL 03-12-21 WY PERMIT SET <br /> 2) EXIT SIGNS SHALL BE LOCATED AS NECESSARY TO CLEARLY APPLICABLE CODES. <br /> 2) THE MAXIMUM UNLATCHING FORCE DOES NOT EXCEED 15 POUNDS (6.8 KG). INDICATE THE DIRECTION OF EGRESS TRAVEL. 8. PROVIDE TACTILE "EXIT" SIGNAGE. AREAS NOT CALCULATED IN OCCUPANCY LOAD: <br /> 3) PIVOTED OR BALANCED DOORS SHALL BE OF THE PUSH-PAD TYPE WHERE 3) NO POINT IN A CORRIDOR SHALL BE MORE THAN 100 FT (30.5 M) OR THE <br /> PANIC HARDWARE IS REQUIRED AND THE PAD SHALL NOT EXTEND ACROSS LISTED VIEWING DISTANCE FOR THE SIGN, WHICHEVER IS LESS, FROM THE 9. PROVIDE INTERNATIONAL SYMBOL OF ACCESSIBILITY SIGN WHERE REQUIRED PATIO SEATING: 247 S.F. <br /> MORE THAN ONE-HALF OF THE DOOR WIDTH, MEASURED FROM THE NEAREST VISIBLE EXIT SIGN. BY APPLICABLE LAWS OR CODES. SHEET TITLE: <br /> 75 LIFE SAFETY AND <br /> n 4) PANIC HARDWARE LISTED IN ACCORDANCE WITH UL 305. F. WHERE KEY OPERATED LOCKING DEVICES ARE USED, POST A SIGN ON OR 10. SEE ENLARGED RESTROOM PLAN AND ELEVATION SHEET FOR ADDITIONAL ACCESSIBILITY PLAN <br /> M ADJACENT TO THE REQUIRED MAIN EXIT DOOR WITH 1 INCH (25 MM) INFORMATION ON ACCESSIBLE RESTROOM CLEARANCES. <br /> 5) FIRE EXIT HARDWARE LISTED IN ACCORDANCE WITH UL 10C AND UL 305. LETTERING STATING THAT"THIS DOOR TO REMAIN UNLOCKED WHEN <br /> p BUILDING IS OCCUPIED". (1008.1.9.3) 11. DOORS IN THE MEANS OF EGRESS SYSTEM TO BE OPENABLE FROM THE SCALE: AS SHOWN <br /> u7 INSIDE W/O ANY USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. <br /> T__ SHEET NUMBER: <br /> N <br /> N <br /> T <br /> co <br /> 002 <br />