Laserfiche WebLink
S0 JOA U 1 Environmental Health Department <br /> U ; i y <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> CUNHA DRAYING INC 1 1500 E MADRUGA RD, LATHROP November 22, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 102 CCR 66262.11 Failed to determine if a waste is a hazardous waste. <br /> OBSERVATIONS: The following were observed in the maintenance shop: <br /> -One oil pan filled with antifreeze observed with no lid or label. Operator states that he does not know if antifreeze is <br /> a waste or product that will be reused. <br /> REGULATION GUIDANCE: Any person who generates a waste shall determine if the waste is a hazardous waste <br /> as specified in Title 22 California Code of Regulations(CCR). There are wastes that are listed as hazardous <br /> wastes. There are wastes that exhibit one or more of the hazardous waste characteristics:toxic, corrosive, reactive <br /> or ignitable. <br /> CORRECTIVE ACTION: Immediately, make a hazardous waste determination for the oil pan with antifreeze, and <br /> manage it according to Title 22 CCR. Use Safety Data Sheets(SDS),waste sampling and test results or other <br /> knowledge to support your hazardous waste determination. Waste testing must be done using methods specified in <br /> Title 22 CCR including sections 66261.20-24. <br /> Submit a statement and supporting documentation with your hazardous waste determination. Demonstrate current <br /> storage and labeling for wastes determined to be hazardous wastes. Provide disposal records for wastes <br /> determined to be hazardous wastes and stored longer than the number of days specified in Title 22 CCR for your <br /> hazardous waste generator status. <br /> This is a Class II violation. <br /> 303 CCR 66262.34(d)(2) Failed to maintain all communication or alarm systems, spill control, or decontamination <br /> equipment. <br /> OBSERVATION: Secondary containment for one approximately 300 gallon used oil tank observed with used oil <br /> accumulating inside. Operator states that he does not know when the last time the secondary containment was <br /> cleaned out. <br /> REGULATION GUIDANCE:All facility communications or alarm systems,fire protection equipment, spill control <br /> equipment, and decontamination equipment,where required, shall be tested and maintained as necessary to assure <br /> its proper operation in time of emergency. <br /> CORRECTIVE ACTION: Bring the secondary containment for the approximately 300 gallon used oil tank into proper <br /> working order by repair, replacement or testing. Provide a corrective action statement to the San Joaquin County <br /> Environmental Health Department within 30 days. <br /> This is a minor violation. <br /> FA0010537 PR0517943 SCO01 11/22/2019 <br /> EHD 22-01 Rev.9/20/2019 Page 4 of 9 Small Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />