My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LONGE
>
7100
>
2200 - Hazardous Waste Program
>
PR0521732
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/1/2020 3:26:00 PM
Creation date
7/1/2020 12:30:31 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0521732
PE
2227
FACILITY_ID
FA0014718
FACILITY_NAME
ENERGY SYSTEMS
STREET_NUMBER
7100
Direction
S
STREET_NAME
LONGE
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
17726028
CURRENT_STATUS
01
SITE_LOCATION
7100 S LONGE ST # 300
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
126
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County AUNDED <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue , Stockton , California 95205-6232 1301M <br /> Telephone: (209 ) 468 -3420 Fax: (209 ) 468 -3433 Web: www. sjgov . org/ehd <br /> Large Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name : Facility Address : Date : <br /> ENERGY SYSTEMS 7100 S LONGE ST , STOCKTON March 26 , 2019 <br /> SUMMARY OF VIOLATIONS <br /> ( CLASS I , CLASS II , or MINOR - Notice to Comply) <br /> Item # Remarks <br /> 403 CCR 66265 . 173 Failed to keep hazardous waste containers closed except when adding or removing hazardous <br /> waste . <br /> In the central accumulation hazardous waste area : <br /> One blue 55 gallon poly drum containing an oily sludge was observed with the bung hole open <br /> One white 30 gallon poly drum containing an oily sludge was observed without a lid <br /> In the fabrication area , one white 5 gallon bucket containing oily metal fines with oil pooling on the bottom of the <br /> bucket was observed without a lid <br /> All hazardous waste containers shall be closed at all times except when adding or removing waste . Immediately <br /> close these containers and ensure all hazardous waste containers are closed when not adding or removing waste . <br /> This is a repeat violation , Class II . <br /> 501 CCR 66262 . 34 (f) Failed to completely label stationary hazardous waste tanks . <br /> The accumulation start date for the used oil tank was incorrect. Records show that there was a pickup after the <br /> 1 /24/2019 listed date . <br /> The used antifreeze tank was observed with a hazardous waste tank label missing the words " Hazardous Waste" <br /> and the accumulation start date . <br /> All hazardous waste tanks shall be marked with the words " Hazardous Waste " and the accumulation start date . <br /> Immediately ensure that all hazardous waste tanks are marked with the required information . <br /> This is a Class II violation. <br /> 502 CCR 66265 . 192 (x) Failed to comply with new hazardous waste tank system assessment requirements . <br /> Facility does not have a tank assessment for the used oil tank and the 150 gallon used antifreeze tank . The owner <br /> or operator of a hazardous waste tank shall obtain a written assessment reviewed and certified by an independent , <br /> qualified , professional engineer, registered in California attesting that the system has sufficient structural integrity, is <br /> acceptable for the transferring , storing , and treating of hazardous waste , and that the tanks and containment system <br /> are suitably designed . Immediately have an assessment prepared for the used oil tank and the 150 gallon used <br /> antifreeze tank . Submit a schedule showing when this will be accomplished to the EHD . <br /> This is a Class I violation. <br /> FA0014718 PR0521732 SCO01 03/26/2019 <br /> EHD 22-02 Rev, 09/22/16 Page 9 of 12 Large Quantity Hazardous Waste Generator OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.