Laserfiche WebLink
CCN TS- STS Sump Test System P9, <br /> Franklin Fueling Systems <br /> Quick Start Guide <br /> TS-STS Overview TS-STS Installation <br /> The TS-STS system includes a TS-STS console within a convenient (D <br /> portable case,leak testing probes with 50 feet of cable,and probe 1.) Required Materials: <br /> hanging hardware(slip rings and chain). <br /> a.) Tape to secure the probe cable b.) Safety cones& signs <br /> After all fittings within the sump are sealed,the sump is filled with a c.) Grounded,3-pronged extension cord <br /> water-based test solution that covers all sump penetration holes.The <br /> probe is installed so the float is floating on the surface of the test solution. d.) Flat pieces of metal to suspend leak testing probe over sumps <br /> The TS-STS console is quickly programmed with the site name and 2) Work safely—install Safety Cones and Signs at the site <br /> address,number of sumps,the 7-digit code-names for each sump,and <br /> the correct Time/Day/Date before leak testing. 3.) The probes are precision instruments—handle with care! <br /> Pressing the Test key at the console keypad starts sump leak tests for 4.) The STS probes are shipped with cables attached,do not remove <br /> all sumps.The test time is 15 minutes and tests for a level change the cable from the probe end...remove at the console case only. <br /> greater than 0.002 inches. If the level of a sump drops more than the 5.) Inspect probes for proper float movement before use,then install <br /> leak limit during the test,the Sump Leak Test Report will show a fail probes as shown in Section 1 <br /> result when the test is finished. Leak tests can also be programmed <br /> (scheduled)to start at desired times. 6.) Connect the yellow probe cables to the receptacles at the TS-STS <br /> When finished,leak test reports will automatically print out at the console case. Make sure to line up keyways before inserting cable and <br /> printer. Extra copies of this report can be printed using the report key.A <br /> tightening the screw-on connector. <br /> newly completed Sump Leak Test will overwrite the previous results 7.) Locate the TS-STS case outside of the Hazardous Area and tape <br /> stored in memory. Save sump leak test reports and provide copies as the cable down to prevent probe movement during the test and to <br /> evidence of compliance with regulations. reduce tripping hazards <br /> Recommendation: Use a computer and the Tech version of 8.) Setup/Program the TS-STS console per Section 2 <br /> System SentinelTm to record site data,sump code-names,and test <br /> results. Test results can also be extracted from Comm Port 1 at 9•) Start sump leak test(s)on sumps that are ready <br /> Nothe bottom of the TS-STS console (also see Section a). 10.) Always clean,dry,and store probes in the probe carrying case after <br /> C=K Reference Federal and State regulations for leak limit and test each use <br /> time requirements. Recommendations for locating the TS-STS <br /> console outside of the(Class 1,Division 1,Group D)Hazardous Areas 11.) Test each of the probes on a monthly basis to ensure its ability to <br /> during testing,are based on NFPA 30,NEPA 30A and NEPA 70(NEC). detect leaks.Install the probe in a test container and initiate a test. <br /> After 5 minutes,remove about 0.12 inches of water.When the test <br /> INCON P/N 000-3004Rev.D Feb.1009® www.(raklinfuelina.com completes,the test report should show a Failed result if the probe <br /> This document may change without prior notice. INCON'is a Registered Trademark of Franklin Fueling Systems <br /> is working properly. <br />