My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SR0070775
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
U
>
UNION
>
181
>
4100 – Safe Body Art
>
SR0070775
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/25/2023 4:29:30 PM
Creation date
7/3/2020 10:13:37 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4100 – Safe Body Art
File Section
COMPLIANCE INFO
RECORD_ID
SR0070775
PE
4102
FACILITY_NAME
ONE SIXTEEN TATTOO
STREET_NUMBER
181
Direction
S
STREET_NAME
UNION
STREET_TYPE
RD
City
MANTECA
Zip
95337
APN
22208027
ENTERED_DATE
10/13/2014 12:00:00 AM
SITE_LOCATION
181 S UNION RD # 10
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\cfield
Supplemental fields
FilePath
\MIGRATIONS\BA\BA_4120_PR0539655_181 S UNION_.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 0 <br /> (3) Place all used or discarded sharps waste in a sharps waste container. <br /> (4) Wash and disinfect reusable instruments. <br /> (5) Package and sterilize reusable instruments that may have come in contact with <br /> non-intact skin or mucosal surfaces. <br /> (6) Decontaminate the workstation and procedure area. <br /> E. Prevention of Cross Contamination: <br /> The practitioner shall maintain a clean and sanitary <br /> environment. <br /> All solid surfaces and objects in the procedure area and the <br /> decontamination and sterilization area that have come into contact <br /> with the client or the materials used in performing the body art, <br /> including, but not limited to, chairs, armrests, tables, countertops, <br /> and trays, shall be immediately decontaminated after each use and <br /> then disinfected by application of a Madacide by spraying the disinfectant directly onto <br /> the surface, let sit for 3 minutes and then wipe down with a disposable paper towel <br /> while wearing single use gloves. <br /> The surfaces and objects in the procedure area shall be disinfected again before use if <br /> the area has been used for any activity following its previous disinfection. <br /> The practitioner shall wear disposable gloves on both hands when touching, <br /> decontaminating, or handling a surface, object or instrument that is soiled or that is <br /> potentially soiled with human blood. <br /> An instrument or other reusable item that comes into contact with non-intact skin or <br /> mucosal surfaces shall either be single use or be washed, disinfected, packaged, and <br /> sterilized after each procedure. Sterilization shall be accomplished pursuant to the <br /> procedures established in Section 119315 by steam autoclave. <br /> An instrument or reusable item that does not come into contact with non-intact skin or <br /> mucosal surfaces shall be washed with a solution of soap and water, using a brush that <br /> is small enough to clean the interior surfaces, and decontaminated after each <br /> procedure. <br /> A reusable item that cannot be immediately washed, disinfected, and sterilized following <br /> completion of the body art procedure shall be placed in a basin of water with or without <br /> detergent. <br /> Sterile instrument packs shall be evaluated before use, and if the integrity of a pack is <br /> compromised in any way, including, but not limited to, being torn, punctured, wet, or <br /> having evidence of potential moisture contamination, the instrument pack shall be <br /> discarded or reprocessed before use. <br /> No food, drink, tobacco product, or personal effects are permitted in the procedure area. <br /> The practitioner shall not eat, drink, or smoke while performing a procedure. If a client <br /> requests to eat, drink, or smoke, the procedure shall be stopped and the procedure site <br /> shall be protected from possible contamination while the client leaves the procedure <br /> area to eat, drink, or smoke. <br /> A product applied to the skin prior to tattooing or application of permanent cosmetics, <br /> including, but not limited to, stencils and marking and transfer agents, including pens, <br /> shall be single use and discarded into a waste container at the end of the procedure <br /> unless the product can be disinfected for reuse. <br />
The URL can be used to link to this page
Your browser does not support the video tag.