Laserfiche WebLink
NLU <br /> 490 East Menlo Ave Hemet CA 92543 LISA <br /> CANSUPPToll-free:1-888-238-0808 or 1-951-765-0808 <br /> www.camtattoo.com Fax:1-951-765-0810 <br /> ETO Sterilization Method <br /> ❖ All items that are to be sterilized are moved to clean rooms where they are prepped for sterilization. <br /> Every product that is sterilized is wiped clean with alcohol soaked cotton ball. (Step 1) <br /> ❖ After being cleaned all products are packed in one of the following FDA Approved packaging: (Step 2) <br /> o Blister packaging <br /> o Sterilization Tubing <br /> o Sterilization pouches <br /> •:* After being sealed in their packages, all products are placed in labeled boxes and sealed. These boxes <br /> are placed into larger boxes and moved to the HDX Sterilization chamber. This is the chamber where all <br /> items are sterilized. (Step 3) <br /> 4- The door is then closed and sealed. This is to ensure that the ETO(ethylene oxide)gas is not leaked. <br /> (Step 4) <br /> 4• The temperature is set between 38°and 2° Celsius. This is done with steam. (Step 5) <br /> *:• When the steam temperature is lower than 30.0%Rh, the steam is released again until the desired <br /> temperature is heated to 50.00%Rh. The control limit is maintained between 30%and 80%Rh. (Step 6) <br /> 4* Form# WI-T-Date is completed verifying process is correct. (Step 7) <br /> 4• Steps 6& 7 are repeated. (Step 8) <br /> +3 Air is vacuumed out of the room. (Step 9) <br /> ❖ Pressure is set at 3.0 KPa—20.0 KPa. (Step 10) <br /> 4• When the pressure reaches between 3,OKPa and 20.OKPa,the vacuuming stops. (Step 11) <br /> ❖ Room is kept at current condition for 3-5 minutes. (Step 12) <br /> •:+ Outer seals are checked again for leaks. (Step 13) <br /> ❖ If when the air is vacuumed out,the moisture level is lower than 30.0%Rh,then the control limit must <br /> be brought back and maintained between 30%and 80%Rh. (Step 14) <br /> •s+ ETO gas is then released into the chamber. (Step 15) <br /> ❖ ETO stays in the chamber for approximately 8.5 hours. (Step 16) <br /> + Computers monitor reactions throughout process. (Step 17) <br /> Alarm sounds when 8.5 hours is completed. (Step 18) <br /> 4• Air is vacuumed again from the chamber. (Step 19) <br /> ❖ Pressure is set at 30.0 KPa for 5 minutes. (Step 20) <br /> • Air is replaced in the chamber. (Step 21) <br /> ❖ Air is vacuumed again. (Step 22) <br /> • Steps 21 &22 are repeated 3 times. (Step 23) <br /> •3 Form# WI-T-date is re-completed. (Step 24) <br /> • Operator prints computer printed WI-T-date and signs his name. (Step 25) <br /> ❖ Door is released and opened. (Step 26) <br /> Products are removed from chamber and indicators are individually checked. If item is not sterile, <br /> process must be re-completed. (Step 27) <br /> ❖ Each box is labeled with the date the process is completed in the following form: <br /> o QP-date <br /> •3 All ETO sterilized items are guaranteed to stay sterile for 2 years or the length of time indicated on <br /> package. <br /> Store in a cool, dry location away from direct sun light. <br /> C.A.M. Supply FDA Registration#: 2085835 <br /> C.A.M. Supply FDA Operator#: 9026450 <br /> C.A.M. Supply 51OK#: K964861 <br />