Laserfiche WebLink
Will 1W <br /> SWIS-09 (REV. 1/85) <br /> NOTICE OF INSPECTION LOCAL EN FO CEMAGENCY: <br /> DISPOSAL SITE <br /> T-our <br /> ji <br /> T-IN <br /> P/kCILiTY NAME <br /> RECEIVED BY: <br /> FACILITY_LOCATI <br /> /� �/ • ':,�' , r;/�, frf''G'' /,�c?x'�.� r.r�" �'f6fta � �!�.�'�� Op9retOr <br /> INSP TOR ' ALfO PR@SENT <br /> `./ Owner <br /> Comments: <br /> o <br /> !a!,?.f <br /> { s, <br /> *V C V C V C V C <br /> (3011) RECORDS EJ ED (3111)CONFINED 0 E (31911 FIRE EJ El (3281) TRAFFIC ❑❑ <br /> ❑ACCURATE WEIGHT/VOLUME UNLOADING ❑FIRE CONTROL ADEQUATE ❑TRAFFIC CONTROL <br /> RECORDS MAINTAINED ❑UNLOADING ADEQUATELY 7703 ADEQUATE WITHIN SITE. <br /> 17636 CONFINED TRAFFIC MINIMIZESINTER- <br /> ❑ADEQUATE SUBSURFACE 17676 (3192) FIRE (P) ❑❑ FEREN CE,SAFETY PROBLEMS, <br /> RECORDS MAINTAINED E]BURNING MATERIALS AND STACKING ON PUBLIC <br /> 17637 (3141)SPREADING/ ❑❑ SPREAD AND EXTINGUISHED. ROADS <br /> ❑LOG OF SPECIAL OCCURRENCES COMPACTING LEA,SWMB NOTIFIED IMMEDI- 17714 <br /> MAINTAINED ❑SPREADING AND COMPACTION ATELY OF FIRE NOT EXTIN- <br /> 17636 IN TWO-FOOT LAYERS GUISHED IN 24 HOURS (3291) EQUIPMENT ❑❑ <br /> ❑RECORDS AVAILABLE FOR 17677 <br /> 17683 ❑EQUIPMENT ADEQUATE IN <br /> INSPECTION TYPE,CAPACITY,AND NUMBER, <br /> 17639 (3151)SLOPES_/CUTS/ ❑❑ (3201) LEACHATE ❑❑ AND IS ADEQUATELY <br /> GRADING ❑ADEQUATE STEPS TAKEN MAINTAINED <br /> (3021) PERSONNEL ❑❑ ❑WORKINGFACE SLOPES TO MONITOR,COLLECT,TREAT, 17726 <br /> ❑ADEQUATE NUMBER OF QUALI- ALLOW EFFECTIVE COMPACTION. AND DISPOSE OF LEACHATES ❑STANDBY EQUIPMENT AVAILABLE <br /> FIED PERSONNEL AVAILABLE DEPTH OF CUTS AND SLOPES 17704 TO C WITH SEC. 17682 <br /> 17616 OF TRENCH SIDES AS ❑NO WASTES IN DIRECT CONTACT AND SECTIONS <br /> ❑PERSONNEL ADEQUATELY TRAINED APPROVED BY LEA WITH WATER EXCEPT AS 17727 <br /> 17647 17678 APPROVED BY RWQCB <br /> ❑ADEQUATE SUPERVISION []FINAL SLOPES HAVE NEAT 17709 (3301) MAINTENANCE ❑❑ <br /> PROVIDED APPEARANCE AND ARE ❑EFFECTIVE MAINTE- <br /> 17648 1-3/4 : 1 OR FLATTER (3202) LEACHATE (P) ❑❑ NANCE PROCEDURES AND <br /> ❑SITE ATTENDANT AVAILABLE 17679 ❑REFUSE COVERED WITH NEXT PROGRAMS DEVELOPED AND <br /> FULL-TIME OR AS DETERMINED ❑GRADING OF FILL SURFACES DAYS REFUSE OR WITH SIX INCHES UTILIZED <br /> BY LEA ADEQUATE OF COMPACTED SOIL.TOTAL AREA 17731 <br /> 17649 17710 OF EXPOSED REFUSEIS AS SPECT- ❑ADEQUATE MONITORING AND <br /> (3031)SIGNS E]ED (3161)COVER El❑ FIED FOR WET AND DRY SEASONS REPAIR OF DETERIORATED <br /> 17683 CONDITIONS <br /> ❑IDENTIFICATION SIGNS AT ❑STOCKPILING OF COVER 17732 <br /> EACH POINT OF ACCESS DOES NOT INTERFERE (321 1) GAS ED EJ17656 WITH OPERATIONS E]GAS MONITORING AND (331 1) CLOSURE EJ ED <br /> 1ENTRY SIGN STATES FEES,HOURS 17680 CONTROL AS REQUIRED ❑AFTER CLOSURE,IF <br /> OF OPERATION,WASTES ❑SUITABLE QUALITY AND 17705 LEACHATE,EXTENSIVE <br /> AC CE <br /> ACCEPTED SUPPLY OF COVER MATERIAL SURFACE CRACKING OR <br /> 17657 AVAILABLE (3221) DUST El SETTLEMENT OCCURS,THE <br /> E]NON-HAZARDOUS UNATTENDED 17681 ❑OUST CONTROL ADEQUATE OWNER SHALL NOTIFY LEA AND <br /> SITES HAVE SIGN WARNING USERS [3 COVER PROVIDED AT REQUIRED 17706 SHALL MONITOR AND REPAIR <br /> OF UNAVAILABILITY OF COMMUNI- DEPTH AND FREQUENCY SITE FOR A PERIOD OF 5YEARS <br /> CATION FACILITIES 17682 (3231) VECTORS/BIRDS ED El OR LONGER <br /> 17668 ❑INTERMEDIATE COVER ❑VECTOR AND BIRD CONTROL 17734 <br /> PROVIDED AT REQUIRED DEPTH ADEQUATE ❑UPON SITECLOSURE,DETAILED <br /> (3041)SECURITY EJ El AND FREQUENCY 17707 DESCRIPTION MUST BE FILED <br /> ❑ADEQUATE PERIMETER 17684 ❑LIQUID PONDS MINIMIZE WITH THE LEA AND WITH THE <br /> SECURITY,HAZARDOUS AREAS V FINAL COVER PROVIDED AS VECTOR PROPAGATION COUNTY RECORDER <br /> FENCED AND IDENTIFIED REQUIRED 17715 17735 <br /> 17658 17685 <br /> (3[]THVECTORS(P) ❑❑ (3321) SPECIAL WASTES ❑❑ <br /> (3051) ROADS ❑❑ (3171)SALVAGING) ❑❑ ❑THRESHOLD VALUES FOR VECTOR ❑BURNING WASTES IMMEDI- <br /> ❑ACCESS ROADS HAVE SMOOTH PROCESSINb POPULATIONS NOT EXCEEDED ATELY SPREAD AND EXTINGUISHED <br /> SURFACE,MINIMIZE DUST AND ID SCAVENGING PROHIBITED 17683 IN SAFE AREA <br /> TRACKING OF MUD,AND 17686 17741 <br /> ALLOW ALL-WEATHER ACCESS F1 SALVAGING DOES NOT INTER- (3241) DRAINAGE/ ❑❑ ❑SITE ACCEPTS ONLY APPROVED <br /> 17659 FERE WITH OPERATIONS EROSION HAZARDOUS WASTES AND <br /> MI NT RNAL ROADS IN SAFE 17687 ❑DRAINAGE AND EROSION TAKES PRECAUTIONS TO <br /> CONDITION,PROVIDE ACCESS ❑VOLUME REDUCTION AND ENERGY CONTROL ADEQUATE ELIMINATE OR CONTROL <br /> DURING INCLEMENT WEATHER, RECOVERY DO NOT INTERFERE 17708 HARMFUL DUSTS,FUMES, <br /> AND ARE PROVIDED WITH WITH OPERATIONS OR CREATE MISTS,VAPORS,OR GASES <br /> DIRECTIONS HEALTH,SAFETY OR ENVIRON- (3251) LITTER El❑ 17742 <br /> 17660 MENTAL PROBLEMS ❑LITTER CONTROL ❑LIQUID WASTES APPROVED BY <br /> 17688 ADEQUATE RWQCB,LOCAL HEALTH ENTITY <br /> (3071)SANITATION ❑❑ ❑SALVAGING AND VOLUME 17711 AND LEA <br /> ❑ADEQUATE SANITARY FACILITIES REDUCTION CONFINED TO 17743 <br /> AVAILABLE CLEARLY IDENTIFIED AREAS (3252) LITTER (P) ❑❑ ❑DEAD ANIMALS ALLOWED BY <br /> 17666 17689 ❑LITTER NOT ALLOWED LOCAL REGULATIONS <br /> ❑SAFE ADEQUATE DRINKING WATER ❑SALVAGE STORAGE LOCATION OK, TO MIGRATE OFF-SITE 17744 <br /> AVAILABLE VOLUME AS APPROVED BY LEA, 17683 <br /> 17667 MINIMIZES FIRE,NUISANCE (3331)OTHER ED <br /> 17690 (3261) NOISE EJ ED ❑ <br /> (3081) COMMUNICATIONS ❑❑ ❑SALVAGESTORAGE TIME DOES NOT ❑NOISE CONTROL <br /> ❑COMMUNICATION FACILITIES RESULT IN HEALTH OR FIRE ADEQUATE '- <br /> AVAILABLE WHERE HAZARDOUS PROBLEMS 1771 <br /> WASTES ARE ACCEPTED 17691 <br /> 17668 ❑SALVAGED MATERIALS APPROVED (3271) ODOR ED E] <br /> (3091) LIGHTING ❑❑ BY LEA AND LOCAL HEALTH E]ODOR CONTROL <br /> 17692 ADEQUATE <br /> ❑LIGHTING ADEQUATE 17713 <br /> 17669 (3181) NUISANCE El ED <br /> ❑OPERATIONS DO NOT CREATE (3272)ODOR (P) El El <br /> 101)SAFETY ElIC NUISANCE ❑AMBIENT AIR AT OR BEYOND <br /> ❑SAFETY EQUIPMENT IN 17701 FACILITY BOUNDARY IS NOT <br /> USE AND BEING WORN ❑FEEDING OF REFUSE TO ANIMALS ODOROUS <br /> 17670 FOR HUMAN CONSUMPTION 17683 *V=Violation <br /> PROHIBITED <br /> 1770z C = Compliance <br /> DISTRIBUTION: WHITE — CWMB YELLOW OPURATOR PINK— LEA <br />