Laserfiche WebLink
City of Stockton TL# 394-0027-02 <br /> March 10, 1994 Page 4 <br /> 4.3 Report <br /> Twining will prepare a letter report describing field activities <br /> with a site location map, site plan showing gas probe locations, <br /> final boring logs, and probe construction diagrams. <br /> 5 .0 SITE SAFETY <br /> Since subsurface contamination is not expected, it is anticipated <br /> that Twining personnel will conduct the proposed work in Level D <br /> protection. The site safety plan is presented in Appendix B. <br /> 6 .0 LIMITATIONS <br /> The proposed work is intended to be an interactive process. <br /> Additional work to more fully assess the extent of methane gas <br /> migration in soil is not anticipated but could become necessary. <br /> No investigation is thorough enough to describe all <br /> geologic/hydrogeologic conditions of interest at a given site. If <br /> conditions are not identified during the study, such a finding <br /> should not be construed as a guarantee of the absence of such <br /> conditions at the site, but rather as the result of the services <br /> performed within the scope, limitations, and cost of the work <br /> performed. <br /> Twining's professional services will be performed, findings <br /> obtained, and conclusions prepared consistent with generally- <br /> accepted environmental assessment principles and practices in San <br /> Joaquin County at the time the work was performed. This warranty <br /> is in lieu of all other warranties, either express or implied. <br />