My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_1996_1
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9069
>
4400 - Solid Waste Program
>
PR0440001
>
ARCHIVED REPORTS_1996_1
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2020 3:53:10 PM
Creation date
7/3/2020 10:40:13 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
1996_1
RECORD_ID
PR0440001
PE
4433
FACILITY_ID
FA0004514
FACILITY_NAME
AUSTIN ROAD/ FORWARD LANDFILL
STREET_NUMBER
9069
Direction
S
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
STOCKTON
Zip
95215
CURRENT_STATUS
02
SITE_LOCATION
9069 S AUSTIN RD
P_LOCATION
01
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440001_9069 S AUSTIN_1996_1.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
460
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SECTION 1 -LANDFILL EXPANSION ISSUES Page 1-8 <br /> Citation Regulation Design Element <br /> Title 23,2543 (c) ..no buildup of hydraulic head on the Sumps are designed be below the <br /> liner.The depth of fluid on the collection collection trench system invert to assure <br /> sump shall be kept at the minimum adequate pump submergence and <br /> needed to ensure efficient pump prevent hydraulic buildup in collection <br /> operation. system. Leachate collection system <br /> designed to keep the maximum head on <br /> the liner less than 12 inches. <br /> Title 23,2543 (d) Leachate collection systems shall be Leachate collection system will include <br /> designed and operated to function without pipe clean-out access points for <br /> clogging ...system tested annually to inspection and flushing of the system. <br /> demonstrate proper operation. <br /> Title 23,2543 (f) Class III landfills required to have an Leachate drainage layer covers full liner <br /> artificial liner...a dendritic leachate area. <br /> collection and removal system which <br /> underlies less than 100 percent of the <br /> waste may be allowed. <br /> Title 23,2543 (g) Collected leachate shall be returned to Leachate recirculation will not be <br /> the waste management unit(s)from which considered as an alternative for leachate <br /> in came or discharged in another manner disposal. Leachate disposal will be off <br /> approved by the regional board. site and require regional board approval. <br /> 01 <br /> CCR 258.40(a) New MSWLF units and lateral expansions Composite liner system is used,leachate <br /> shall be constructed: collection system is designed to maintain <br /> (1) In accordance with a design approved leachate depth at 12 inches or less. (30 <br /> by the Director of approved state...or(2) cm equals approximately 12 inches). <br /> With a composite liner as defined in <br /> paragraph (b) of this section and a <br /> leachate collection system that is <br /> designed and constructed to maintain <br /> less than a 30-cm depth of leachate over <br /> the liner. <br /> 258.40(b) Composite liner means a system con- Composite liner consists of a 60-mil mini- <br /> sisting of two components; ... a minimum mum HDPE geomembrane and a 2-foot <br /> of 30-mil flexible membrane liner(FML) compacted clay layer with a maximum <br /> ... and ... at least a 2-foot layer of hydraulic conductivity of 1 x 17'cm/sec. <br /> compacted soil with a hydraulic conduc- <br /> tivity of no more than 1 x 10''cm/sec. <br /> FML components consisting of HDPE <br /> shall be at least 60-mil thick.The FML <br /> component must be installed in direct and <br /> uniform contact with the compacted soil <br /> component. <br /> 1.3.3 Landfill Liner System <br /> J <br /> The proposed landfill liner on both the horizontal and vertical expansions is a composite system, <br /> which consists of a geomembrane liner underlain by two feet of compacted clay soil with a <br /> maximum permeability of 1 x 10-7 cm/sec. This liner will meet the requirements of CCR 258.40 <br /> R.W.ee�x AssociatesGtrm stocition <br /> 1811.002 <br /> � II <br />
The URL can be used to link to this page
Your browser does not support the video tag.