My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_1996_2
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9069
>
4400 - Solid Waste Program
>
PR0440001
>
ARCHIVED REPORTS_1996_2
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2020 3:53:09 PM
Creation date
7/3/2020 10:40:16 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
1996_2
RECORD_ID
PR0440001
PE
4433
FACILITY_ID
FA0004514
FACILITY_NAME
AUSTIN ROAD/ FORWARD LANDFILL
STREET_NUMBER
9069
Direction
S
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
STOCKTON
Zip
95215
CURRENT_STATUS
02
SITE_LOCATION
9069 S AUSTIN RD
P_LOCATION
01
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440001_9069 S AUSTIN_1996_2.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
465
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STANDARD PROVISIONS AND REPORTING REQUIREMENTS September 1993 <br />FOR WASTE DISCHARGE REQ NTS <br />FOR DISCHARGES REGULATED BY CHAPTER 15 AND/OR PART 258 -9- <br />5. MDLs and PQLs shall be derived by the laboratory for each analytical procedure, according <br />to State of California laboratory accreditation procedures. These MDLs and PQLs shall reflect <br />the detection and quantitation capabilities of the specific analytical procedure and equipment <br />used by the lab, rather than simply being quoted from USEPA analytical method manuals. In <br />relatively interference -free water, laboratory -derived MDLs and PQLs are expected to closely <br />agree with published USEPA MDLs and PQLs. <br />If the lab suspects that, due to a change in matrix or other effects, the true detection limit or <br />quantitation limit for a particular analytical run differs significantly from the laboratory - <br />derived MDIJPQL values, the results shall be flagged accordingly, along with estimates of the <br />detection limit and quantitation limit actually achieved. The MDL shall always be calculated <br />such that it represents a concentration associated with a 99% reliability of a non -zero result. <br />The PQL shall always be calculated such that it represents the lowest constituent concentration <br />at which a numerical value can be assigned with reasonable certainty that it represents the <br />constituent's actual concentration in the sample. Normally, PQLs should be set equal to the <br />concentration of the lowest standard used to calibrate the analytical procedure. <br />6. All QA/QC data shall be reported, along with the sample results to which they apply, <br />including the method, equipment, and analytical detection and quantitation limits, the percent <br />recovery, an explanation for any recovery that is less than 80%, the results of equipment and <br />method blanks, the results of spiked and surrogate samples, the frequency of quality control <br />analysis, and the name and qualifications of the person(s) performing the analyses. Sample <br />results shall be reported unadjusted for blank results or spike recoveries. In cases where <br />contaminants are detected in QA/QC samples (i.e., field, trip, or lab blanks), the accompanying <br />sample results shall be appropriately flagged. <br />7. Unknown chromatographic peaks shall be reported, along with an estimate of the <br />concentration of the unknown analyte. When unknown peaks are encountered, second column <br />or second method confirmation procedures shall be performed to attempt to identify and more <br />accurately quantify the unknown analyte. <br />Analysis of Monitoring Data <br />Officer, the Discharger shall use <br />Unless an alternate method has been approved by the Executive Off <br />one of the following methods, according to the method selection procedure below— <br />One-Way Parametric Analysis of Variance (ANOVA), <br />One -Way Non -Parametric ANOVA (Kruskal-Wallis Test), <br />Method of Proportions, or <br />non -statistical method <br />—to compare the downgradient concentration of each monitored constituent or parameter with its <br />respective background concentration to determine if there has been a release from the WMU. <br />
The URL can be used to link to this page
Your browser does not support the video tag.