My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_1996_2
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9069
>
4400 - Solid Waste Program
>
PR0440001
>
ARCHIVED REPORTS_1996_2
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2020 3:53:09 PM
Creation date
7/3/2020 10:40:16 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
1996_2
RECORD_ID
PR0440001
PE
4433
FACILITY_ID
FA0004514
FACILITY_NAME
AUSTIN ROAD/ FORWARD LANDFILL
STREET_NUMBER
9069
Direction
S
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
STOCKTON
Zip
95215
CURRENT_STATUS
02
SITE_LOCATION
9069 S AUSTIN RD
P_LOCATION
01
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440001_9069 S AUSTIN_1996_2.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
465
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STANDARD PROVISIONS AND REPORTING REQUIREMENTS September 1993 <br />FOR WASTE DISCHARGE REQUIREMENTS <br />FOR DISCHARGES REGULATED BY CHAPTER 15 AND/OR PART 258 -11- <br />taking more than four samples per Monitoring Point, based upon past monitoring results. <br />The ANOVA shall be carried out at the 95% confidence level. Following the ANOVA, <br />the data from each downgradient Monitoring Point shall be tested at a 99% confidence <br />level against the pooled background data. If these multiple comparisons cause the Null <br />Hypothesis (i.e., that there is no release) to be rejected at any Monitoring Point, the <br />Discharger shall conclude that a release is tentatively indicated for that parameter or <br />constituent. <br />C. The Method of Proportions shall be used if the "combined data set"—the data from a <br />given Monitoring Point in combination with the data from the Background Monitoring <br />Points—has between 50% and 90% of the data below the MDL for the constituent or <br />parameter in question. <br />This method requires— <br />i. at least nine downgradient data points per Monitoring Point per Reporting Period, <br />I at least thirty data points in the combined data set, and <br />iii. that n * P > 5 [where n is the number of data points in the combined data set and <br />P is the proportion of the combined set that equals or exceeds the MDL]. <br />Therefore, the Discharger shall anticipate the number of samples required, based upon <br />past monitoring results. The test shall be carried out at the 99% confidence level. If the <br />analysis results in rejection of the Null Hypothesis [i.e., that there is no release], the <br />Discharger shall conclude that a release is tentatively indicated for that constituent or <br />parameter. <br />2. The Discharger shall use the following non -statistical method for the VOC water and VOC spg <br />Monitoring Parameters and for all Constituents of Concern which are not amenable to the <br />statistical tests above (i.e., less than 10% of the data from background samples equal or exceed <br />their respective MDL). <br />Each qualifying constituent at a Monitoring Point shall be determined based on either— <br />(1) the data from a single sample for that constituent, taken during that Reporting Period <br />from that Monitoring Point, or <br />(2) (where several independent samples have been analyzed for that constituent at a given <br />Monitoring Point) the data from the sample which contains the largest number of <br />qualifying constituents. <br />Background shall be represented by the data from all samples taken from Background <br />Monitoring Points during that Reporting Period (at least one sample from each Background <br />Monitoring Point). <br />The method shall be implemented as follows: <br />
The URL can be used to link to this page
Your browser does not support the video tag.