Laserfiche WebLink
MONITORING WELL PURGING PROTOCOL <br /> MEASURE AND RECORD DEPTH TO WATER AND <br /> WELL TOTAL DEPTH <br /> CALCULATE PURGE VOLUME BY <br /> USING THE FOLLOWING EQUATION: <br /> P=nr2hx7.48x3 <br /> where: <br /> P=calculated purge volume(gallons) <br /> a=3.14 <br /> r=radius of well casing in feet <br /> ' h=height of water column in feet <br /> EVACUATE WATER FROM WELL EQUAL TO <br /> ' THE CALCULATED PURGE VOLUME WHILE <br /> MONTTORING GROUNDWATER <br /> STABILIZATION INDICATOR PARAMETERS <br /> ' (pH,CONDUCTIVITY,TEMPERATURE)AT <br /> INTERVALS OF ONE CASING VOLUME. <br /> WELL EVACUATED TO PRACTICAL LIN[ITS <br /> OF DRYNESS BEFORE REMOVING <br /> CALCULATED PURGE VOLUME <br /> NO YES <br /> FINAL TWO SETS OF GROUNDWATER <br /> STABILIZATION INDICATOR PARAMETER <br /> ' MEASUREMENTS MEET THE FOLLOWING <br /> CRITERIA: WELL RECHARGES TO A LEVEL <br /> pH =t 0.1 pH units SUFFICIENT FOR SAMPLE <br /> ' COND. =+ 10% COLLECTION WITHIN 24-HOURS <br /> TEMP. =t 1.0 OF OF EVACUATION TO DRYNESS. <br /> YES NO YES NO <br /> ' WELL PURGING CONTINUE PURGING;EVACUATE FIELD TEST FIRST RECORD WELL <br /> CRITERIA MET; ADDITIONAL CASING VOLUME RECHARGE WATER FOR AS DRY FOR <br /> PROCEED TO OF WATER,MONITORING INDICATOR PARAMETERS, PURPOSES OF <br /> ' WELL SAMPLING. INDICATOR PARAMETERS FOR THEN PROCEED TO WELL SAMPLING. <br /> STABILITY. SAMPLING. <br /> ' FIGURE <br /> E CON MONITORING WELL PURGING PROTOCOL C®1 <br />