Laserfiche WebLink
e <br /> San Joaquin Valley <br /> Air Pollution Control District <br /> 'ERMIT UNIT: N-3303-1-1 EXPIRATION DATE: 08/31/2006 <br /> :QUIPMENT DESCRIPTION: <br /> .ANDFILL GAS COLLECTION SYSTEM SERVED BY TWO HAUCK MANUFACTURING CO. BLOWERS RATED AT 500 <br /> ;CFM EACH AND ONE 17 MMBTU/HR SUR-LITE MODEL MADISON LANDFILL GAS FIRED FLARE WITH A LANDFILL <br /> :,AS CONDENSATE INJECTION SYSTEM. <br /> PERMIT UNIT REQUIREMENTS <br /> No air contaminant shall be released into the atmosphere which causes a public nuisance. [District Rule 41021 <br /> No air contaminant shall be discharged into the atmosphere for a period or periods aggregating more than three <br /> minutes in any one hour which is as dark as,or darker than,Ringelmann I or 20%opacity. [District Rule 4101] <br /> c. Particulate matter emissions shall not exceed 0.1 grains/dscf in concentration. [District Rule 4201] <br /> L The gas collection system shall be operated in such a manner to prevent overdraw that can cause fires or damage to the <br /> gas collection system. [District Rule 4642] <br /> >. Owner/operator shall maintain non-resettable,totalizing volumetric fuel flow meter that measures the daily quantity of <br /> landfill gas condensate injected.[District Rule 4642] <br /> >. .. er/operator shall maintain and operate the landfill gas flare in accordance with the manufacturer's specifications <br /> n accordance with Section 5.2.4 of District Rule 4642(Solid Waste Disposal Sites). [District Rule 46421 <br /> T. The thermocouple probe used to measure the flare temperature shall be located above the flame zone,a minimum of <br /> three (3)feet below the top of the flare shroud, and at least 0.6 second downstream of the burner. [District Rule 46421 <br /> 3. The flare shall be equipped with a temperature indicator, a gas flow indicator and a recorder that records the gas <br /> temperature in the flare stack, and the quantity of landfill gas consumed. The temperature and gas flow shall be <br /> recorded continuously. [District Rule 46421 <br /> ). A temperature of at least 1,475 degrees F, measured at the thermocouple probe,must be maintained when the flare is <br /> in operation. [District Rule 46421 <br /> [0. The methane content of the landfill gas shall not exceed 55%. [District Rule 2201] <br /> 11. The landfill gas condensate injection rate shall not exceed 0.6 gallon per minute. [District Rule 220 1] <br /> 12. Emissions from the flare shall not exceed any of the following limits: 0.06 lb-NOx/MMBtu,0.02991b-SOX/MMBtu, <br /> 0.0425lb-PM IO/MMBtu,0.20 lb-CO/MMBtu,or 0.03 lb-VOC/MMBtu. [District Rule 2201] <br /> 13. The District shall be notified of any breakdown conditions in accordance with Rule 1100(Equipment Breakdown). <br /> [District Rule I 100 <br /> 14. Owner/operator shall notify the APCO by telephone at least 24 hours before performing any maintenance that requires <br /> the system to be shutdown.The notification shall include a description of the maintenance,the date maintenance will <br /> be performed and the amount of time needed to complete the maintenance. [District Rule 4642] <br /> 15_ During maintenance of the gas collection system or the flare,emissions of landfill gas into atmosphere shall be <br /> minimized during shutdown. The gas collection system and the flare shall not be shutdown for more than 144 <br /> ulative hours in any calendar year. [District Rule 4642] <br /> 16: _ e destruction efficiency for non-methane hydrocarbons shall be at least 98%at all times. [District Rule 46421 <br /> OZC. PERMIT UNIT REQUIREMENTS CONTINUE ON NEXT PAGE <br /> These terms and conditions are part of the Facility-wide Permit to Operate. <br /> Facility Name: SAN JOAQUIN CO.PUBLIC WORKS <br /> Location: 14750 E.HARNEY LANE,LODI,CA <br /> M3303-1-1 10 14 2004 216PM-SCHOMIOM <br />