Laserfiche WebLink
11 <br />0 <br />it <br />C� <br />CI <br />U <br />u <br />L <br />Ll <br />Ci <br />Inorganic Data Qualifiers <br />The result is an outlier. See case narrative. <br /># The control limit criteria is not applicable. See case narrative. <br />B The analyte was found in the associated method blank at a level that is significant relative to the sample result. <br />E The result is an estimate amount because the value exceeded. the instrument calibration range. <br />J The result is an estimated concentration that is less than the MRL but greater than or equal to the MDL. <br />U The compound was analyzed for, but was not detected ("Non -detect") at or above the MRUMDL. <br />i The MRL/MDL has been elevated due to a matrix interference. <br />X See case narrative. <br />Metals Data Qualifiers <br /># The control limit criteria is not applicable. See case narrative. <br />B The result is an estimated concentration that is less than the MRL but greater than or equal to the MDL. <br />E The percent difference for the serial dilution was greater than 10%, indicating a possible matrix interference in the sample. <br />M The duplicate injection precision was not met. <br />N The Matrix Spike sample recovery is not within control limits. See case narrative. <br />S The reported value was determined by the Method of Standard Additions (MSA). <br />U The compound was analyzed for, but was not detected ("don -detect") at or above the MRLIMDL. <br />W The post -digestion spike for furnace AA analysis is out of control limits, while sample absorbance is less than 50% of spike <br />absorbance. <br />i The MRUMDL has been elevated due to a matrix interference. <br />X See case narrative. <br />* The duplicate analysis not within control limits. See case narrative. <br />-I- The correlation coefficient for the MSA is less than 0.995. <br />Organic Data Qualifiers <br />* The result is an outlier. See case narrative. <br /># The control limit criteria is not applicable. See case narrative. <br />A A tentatively identified compound, a suspected aldol -condensation product. <br />B The analyte was found in the associated method blank at a level that is significant relative to the sample result. <br />C The analyte was qualitatively confirmed using GC/MS techniques, pattern recognition, or by comparing to historical data. <br />D The reported result is from a dilution. <br />E The result is an estimate amount because the value exceeded the instrument calibration range. <br />J The result is an estimated concentration that is less than the MRL but greater than or equal to the MDL. <br />N The result is presumptive. The analyte was tentatively identified, but a confirmation analysis was not performed. <br />P The GC or HPLC confirmation criteria was exceeded. The relative percent difference is greater than 40% between the two <br />analytical results (25% for CLP Pesticides). <br />U The compound was analyzed for, but was not detected ("Iron -detect') at or above the MRUMDL. <br />i The MRUMDL has been elevated due to a chromatographic interference. <br />X See case narrative. <br />Additional Petroleum Hydrocarbon Specific Qualifiers <br />r The chromatographic fingerprint of the sample matches the elution pattern of the calibration standard. <br />L The chromatographic fingerprint of the sample resembles a petroleum product, but tate elution pattern indicates the presence of <br />a greater amount of lighter molecular weight constituents than the calibration standard. <br />H The chromatographic fingerprint of the sample resembles a petroleum product, but the elution pattern indicates the presence of <br />a greater amount of heavier molecular weight constituents than the calibration standard. <br />0 The chromatographic fingerprint of the sample resembles an oil, but does not match the calibration standard. <br />,i, The chromatographic fingerprint of the sample resembles a petroleum product eluting in approximately the correct carbon <br />range, but the elution pattern does not match the calibration standard. <br />7 The chromatographic fingerprint does not resemble a petroleum product. 33 <br />