Laserfiche WebLink
A 0, 41W .0 X TRUENVIRON MENTAL, INC. <br />A Texas Research Intemational Company <br />GCL TEST RESULTS <br />TRI Client: Vector Engineering, Inc. <br />Project: Forward Landfill <br />Material: Bentofix GCL <br />Sample Identification: 86928 <br />TRI Log #: E2161-76-05 <br />1 2 3 <br />Bentonite - Mass/Unit Area <br />(ASTM D 5993, result @ 12% M.C.) <br />Bentonite mass/unit area (Ibs/112) 1.06 0.99 1.00 <br />Moisture Content (%) 10.7 11.3 11.0 <br />4 5 6 7 8 9 10 <br />1.00 1.03 <br />11.2 10.7 <br />Peel Strength <br />(ASTM D 4632, modified for 180 degree peel of GCL) <br />MD - Peel Strength (lbs) 48 49 50 52 <br />Hydraulic Conductivity - ASTM D 5084 <br />(5 psi effective stress) <br />Hydraulic Conductivity (cm/sec) 1.4E-09 <br />MD Machine Direction <br />TD Transverse Direction <br />i§ �c.. <br />1.02 1 0.03 1.0 min <br />11.0 0.25 <br />54 51 46 50 50 48 1r 50 2 15 min <br />1.4E-09 5E-9 max <br />The testing herein is based upon accepted industry practice as well as the test method listed. Test results reported herein do not apply <br />to samples other than those tested. TRI neither accepts responsibility for nor makes claim as to the final use and purpose of the material. <br />TRI observes and maintains client confidentiality. TRI limits reproduction of this report, except in full, without prior approval of TRI. <br />9063 Bee Caves Road / Austin, Texas 78733 / 512 263 2101 / 512 263 2558 <br />3of3 <br />