My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
CORRESPONDENCE_2006-2009
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
4400 - Solid Waste Program
>
PR0440005
>
CORRESPONDENCE_2006-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/3/2025 2:07:00 PM
Creation date
7/3/2020 10:50:17 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
CORRESPONDENCE
FileName_PostFix
2006-2009
RECORD_ID
PR0440005
PE
4433 - LANDFILL DISPOSAL SITE
FACILITY_ID
FA0004516
FACILITY_NAME
FORWARD DISPOSAL SITE
STREET_NUMBER
9999
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
201060013, 5
CURRENT_STATUS
Active, billable
SITE_LOCATION
9999 AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\cfield
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440005_9999 AUSTIN_2006-2009.tif
Site Address
9999 AUSTIN RD MANTECA 95336
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
494
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Cleanup and Abatement Ord -2008-0714 <br />Forward Landfill <br />San Joaquin County <br />11. Significant volatile organic compound (VOC) groundwater impacts including, but not <br />limited to, 1,1-dichloroethane, cis- 1,2-d ichloroethylene, tetrachloroethylene, and <br />trichloroethylene are associated with waste discharged to the Austin Road Landfill. <br />Impacts were initially detected in 1989. By 1991, evaluation monitoring determined <br />that chlorinated hydrocarbon impacts extended as far as 1,000 feet down -gradient <br />"from the Austin Road Landfill. A corrective action plan, consisting of a phased <br />approach to remediate the plume, was approved in 1991, but by 1998 it was <br />apparent that the initial corrective actions had failed to remediate the groundwater <br />impacts because detections of 1,1-dichloroethane, cis-1,2-dichloroethylene, <br />tetrachloroethylene, and trichloroethylene were still detected in downgradient <br />monitoring wells. <br />12. The Discharger stated in its 2002 Joint Technical Document that "the VOC polluted <br />groundwater extends approximately 4,000 feet northeast from the northern border of <br />the existing -Austin Road Landfill. The -plume appears to -have migrated to -a lower <br />depth at the leading edge of the plume. The primary contaminants of concern are <br />Tetrachloroethylene and Trichloroethene, with concentrations levels up to 59 and 48 <br />micrograms per liter, respectively. The highest VOC concentrations are present <br />within a sand layer that extends beneath the site between approximately 80 to 104 <br />feet below ground surface." <br />13. There are no monitoring wells at the downgradient edge (vertically or laterally) of the <br />plume. <br />14. In 2003, the Central Valley Water Board adopted WDRs Orders R5-2003-0049 and <br />R5-2003-0080 to implement revised corrective actions to remediate groundwater <br />impacts. The Discharger extracts groundwater from two wells adjacent to the <br />northern boundary of the Austin Road Landfill, and then runs it through an air <br />sparger prior to discharging the effluent to an infiltration area. From 1 October <br />through 31 December 2007, the two wells extracted at an average rate of 209 <br />gallons per minute or 301,000 gallons per day. Based on the continuing detections in <br />the downgradient wells, the current extraction rate is insufficient to control the plume <br />and remediate the release of groundwater pollutants from the landfill. <br />15. The Austin Road Landfill corrective action monitoring system includes monitoring <br />wells AMW 13 and AMW 14. These wells are approximately 1,600 feet directly <br />downgradient of the two extraction wells EW -1 and EW -2. During the first Quarter <br />2008 sampling event the following VOCs concentrations were detected in these <br />wells: <br />
The URL can be used to link to this page
Your browser does not support the video tag.