Laserfiche WebLink
THIRD QUARTER 2007 GROUNDWATER TREATMENT FACILITY MONITORING REPORT <br /> FORWARD LANDFILL WDR ORDER NO.R5-2003-0080 <br /> All parameters other than dissolved inorganics were analyzed during third quarter 2007. <br /> Figure 1 (at the end of this report) shows the effluent monitoring location.Table 2 presents <br /> the results of the effluent monitoring performed during third quarter 2007. Appendix A <br /> contains the effluent monitoring field sampling logs and Iaboratory results for third <br /> quarter 2007. <br /> TABLE 2 <br /> Effluent Monitoring Results <br /> Third Quarter 2001 Groundwater Treatment Facility Monitoring Report,Forward Landfill WEIR Order No.R5-2003-0080 <br /> Analysis Date Parameters Units Results <br /> Field Parametersa <br /> 7/02/07 pH pH units 7.8 <br /> Conductivity µmhos/cm 758 <br /> 8/02/07 pH pH units 7.4 <br /> Conductivity µmhos/cm 1,020 <br /> 9/17/06 pH pH units 7.8 <br /> Conductivity µmhos/cm 970 <br /> Laboratory Analysesb <br /> 7/02/07` All VOCs pg/L Nondetect <br /> Total dissolved solids milligrams per liter 545 <br /> 8/02/07d All VOCs pg/L Nondetect <br /> 8/16/074 All VOCs pg/L Nondetect <br /> 9/10/07d All VOCs pg/L Nondetect <br /> aField parameters were analyzed using a calibrated Horiba U-10 water quality meter. <br /> bVOCs were analyzed using U.S. Environmental Protection Agency Method SW8260B.Total dissolved solids <br /> were analyzed using U.S. Environmental Protection Agency Method 160.1. <br /> Only EW-1 was operational when this sample was collected. <br /> dBoth extraction wells were operational when this sample was collected. <br /> Notes: <br /> pg/L = micrograms per liter <br /> µmhos/cm = micromhos per centimeter <br /> The current WDRs stipulate that the concentration limit for VOCs in the effluent is non- <br /> detect.TCE was initially detected in the effluent sample collected on August 2,2007,at an <br /> estimated concentration (0.36 pig/L) slightly above the method detection limit(0.15 pg/L). <br /> The TCE detection appeared to be anomalous.TCE had not previously been detected in the <br /> GTF effluent. <br /> The CV Water Board was informed of the August effluent sample results on August 15,2007 <br /> (Burke,2007,personal communication). After discussions with the CV Water Board,a <br /> confirmation effluent sample was collected on August 16,2007, and the GTF was then shut <br /> down.On August 16,2007,the analytical laboratory reported that the TCE detection in the <br /> August 2 effluent sample was the result of carryover from a previously analyzed sample. <br /> The laboratory reanalyzed the August 2,2007,effluent sample within holding time on <br /> August 16,2007,and no VOCs were detected.The laboratory issued an amended analytical <br /> report for the August 2,2007, sample results.The laboratory analyzed the confirmation <br /> effluent sample on August 17,2007,using a same-day turnaround time and no VOCs were <br /> RDD/072830006(CLR3709.DOC) 4 <br />