Laserfiche WebLink
Troubleshooting <br />If you encounter problems with the Drain Gauge sensor, <br />they most likely will manifest themselves in the form of <br />incorrect or erroneous readings. Before contacting Deca- <br />gon about the sensor, do the following: <br />ii <br />29 <br />V <br />Drain Gauge User's Manual <br />4. Collecting Data <br />2: -1 F <br />3: 4 Z Loc [ counter J <br />;Output time and water level data to <br />;final storage for 10s siphon chamber <br />'flushing event <br />9: Do (P86) <br />1: 10 Set Output Flag High (Flag 0) <br />10: Real Time (P77) <br />1: 1111 Year,Day,Hour/Minute,Seconds (midnight = 0000) <br />11: Sample (P70) <br />1: 1 Reps <br />2: 1 Loc [ WatrLevel ] <br />12: End (P95) <br />;Output time and water level every hour. ;These data provide <br />information about <br />;infiltration events that are not large <br />;enough to cause gauge to flush, and are also <br />;useful to ensure that program is catching <br />;all gauge flush events <br />13: If time is (P92) <br />1: 0 Minutes (Seconds --) into a <br />2: 60 Interval (same units as above) <br />3: 10 Set Output Flag High (Flag 0) <br />14: Real Time (P77) <br />1: 1110 Year,Day,Hour/Minute (midnight = 0000) <br />15: Sample (P70) <br />1: 1 Reps <br />2: 1 Loc [ WatrLevel ] <br />*Table 2 Program <br />02: 0.0000 Execution Interval (seconds) <br />*Table 3 Subroutines <br />End Program <br />Troubleshooting <br />If you encounter problems with the Drain Gauge sensor, <br />they most likely will manifest themselves in the form of <br />incorrect or erroneous readings. Before contacting Deca- <br />gon about the sensor, do the following: <br />ii <br />29 <br />V <br />