6ME <br />Accredited by <br />U.S. Dept. offmerce <br />RI vr,& <br />ASBESTOS TEM LABORATORIES, INC NVLAP LAB CODE 101891-0 <br />A DOHS FLAP <br />Aug/01/2007 <br />Rajan <br />Shaw Environmental & Infrastruture <br />2360 Bering Drive <br />San Jose, CA 95131 <br />RE: LABORATORY JOB # 1199-00001 <br />Transmission electron microscopy analytical results for 6 air sample(s). <br />Job Site: <br />Job No.: <br />Enclosed please find results for the TEM analysis of one or more air samples. The analytical procedures were <br />performed according to the NIOSH 7402 (Revision # 1) method. Prior to analysis, samples are checked for damage <br />and disruption of the chain -of -custody seal. Samples are then logged -in, each given a unique laboratory number, and <br />a hard copy containing all pertinent information is generated. This, and all other relevant paper work are kept with <br />each sample throughout the analytical procedures to assure proper analysis. <br />Preparation of air filter cassettes is performed within a NEPA filtered, Class 100 air, laminar flow clean bench <br />environment. Cassettes are wet -wiped to remove any external contamination prior to placement into the clean bench <br />area. Sections of the filters are removed, placed onto glass microscope slides, and collapsed in acetone vapor. The <br />collapsed filters are plasma etched, removing the surface of the filter to a depth of ten percent of its -original thickness, <br />then carbon coated. The filters are further sectioned and placed carbon side up onto 200 -mesh copper TEM sample <br />grids in an acetone wick washer to remove falter material The grids are placed into labeled containers and loaded into <br />the microscope for analysis. <br />TEM analysis is performed on a Philips EM -300 transmission electron microscope operating at 80 or 100 kV,.with a <br />magnification as indicated on the analytical report. A known area of the specimen surface is scanned for fibrous <br />structures. All structures exhibiting an aspect ratio greater than or equal to 3 to 1, and a length greater than or equal <br />to 5.0 um are subjected to detailed morphological and selected area diffraction (SAED) analysis. Structures indicated <br />as asbestos, or potentially asbestos, are further analyzed by energy dispersive X-ray (EDX) analysis as needed. <br />Analysis continues until 100 asbestiform structures are found, or an analytical sensitivity of 0.001 structures/cc is <br />attained, or 40 grid openings are analyzed. Data is compiled into a standard report format and subjected to a thorough <br />quality assurance check before the information is released to the client. <br />Sincerely Yours, <br />Laboratory Manager <br />ASBESTOS TEM LABORATORIES, INC. <br />— These results relate only to the samples tested and must not bereproduced, except in full, with the approval of the <br />laboratory. This report must not be used to claim product endorsement by NVLAP or any other agency of the U.S. <br />Government. — <br />630 BANCROFT WAY o BERKELEY, CA 94710 • (510) 704-8930 • FAX(510)704-8429 <br />www.asbestostemlabs.com With OjJices in Reno, NY (775) 359-3377 <br />