My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_2008
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
4400 - Solid Waste Program
>
PR0440005
>
Archived Reports
>
ARCHIVED REPORTS_2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/18/2020 12:09:58 AM
Creation date
7/3/2020 10:53:19 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
2008
RECORD_ID
PR0440005
PE
4433
FACILITY_ID
FA0004516
FACILITY_NAME
FORWARD DISPOSAL SITE
STREET_NUMBER
9999
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20106001-3, 5
CURRENT_STATUS
01
SITE_LOCATION
9999 AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440005_9999 AUSTIN__1.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
564
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
® CA DPH ELAP ( { <br /> Lab No. 1866 U V <br /> ASBESTOS TEM LABORATORIES, INC NVLAP Lab Code:101891-0 <br /> Berkeley,CA <br /> Oct/30/2014 <br /> Don Light <br /> Del-Tech Geotechnical Support,Inc. <br /> 645 N.Yosemite Ave <br /> Oakdale,CA 95361 <br /> RE: LABORATORY JOB# 1323-00010 <br /> Transmission electron microscopy analytical results for 5 air sample(s). <br /> Job Site: Fall Air Monitoring 2014 <br /> Job No.: Spring Semi-Annual Asb.Air <br /> Enclosed please find results for the TEM analysis of one or more air samples.The analytical procedures were <br /> performed according to the NIOSH 7402(Revision#1) method. Prior to analysis, samples are checked for <br /> damage and disruption of the chain-of-custody seal. Samples are then logged-in,each given a unique laboratory <br /> number,and a hard copy containing all pertinent information is generated. This,and all other relevant paper work <br /> are kept with each sample throughout the analytical procedures to assure proper analysis. <br /> Preparation of air filter cassettes is performed within a NEPA filtered,Class 100 air,laminar flow clean bench <br /> environment. Cassettes are wet-wiped to remove any external contamination prior to placement into the clean <br /> bench area. Sections of the filters are removed,placed onto glass microscope slides,and collapsed in acetone <br /> vapor. The collapsed filters are plasma etched,removing the surface of the filter to a depth of ten percent of its <br /> original thickness,then carbon coated. The filters are further sectioned and placed carbon side up onto 200-mesh <br /> copper TEM sample grids in an acetone wick washer to remove filter material. The grids are placed into labeled <br /> containers and loaded into the microscope for analysis. <br /> TEM analysis is performed on a Philips CM-12 or EM-300 transmission electron microscope operating at 80 or <br /> 100 kV,with a magnification as indicated on the analytical report. A known area of the specimen surface is <br /> scanned for particles meeting the OSHA definition of a fiber(a particle with diameter greater than 0.25 microns in <br /> width,a length greater than 5.0 microns and an aspect ratio greater than or equal to 3 to 1).Each fiber is subjected <br /> to detailed morphological and selected area diffraction(SAED)analysis. Fibers indicated as asbestos,or <br /> potentially asbestos,are further analyzed by energy dispersive X-ray(EDX)analysis as needed.Analysis continues <br /> until either completion of the grid opening containing the 50th asbestos fiber,or until 40 TEM grid openings are <br /> analyzed. Data is compiled with results reported as PCM equivalent(PCME)asbestos fibers/cc air and released to <br /> the client. <br /> Sincerely Yours, <br /> Laboratory Manager <br /> ASBESTOS TEM LABORATORIES,INC. <br /> --These results relate only to the samples tested and must not bereproduced,except in full,with the approval of <br /> the laboratory. This report must not be used to claim product endorsement by NVLAP or any other agency of the <br /> U.S.Government.--- <br /> 630 BANCROFT WAY • BERKELEY,CA 94710 • (510)704-8930 • FAX(510)704-8429 <br /> www.asbestostemlabs.com With Offices in Reno, NV(775)359-3377 <br />
The URL can be used to link to this page
Your browser does not support the video tag.