Laserfiche WebLink
TRANSMISSION ELECTRON MICROSCOPY <br /> ANALYTICAL T <br /> AHERA Analysis Method <br /> Contact: Bill Johnston Report No.: 079905 <br /> Address: Shaw Environmental&Infrastructure <br /> Date: Oct-18-09 <br /> 767 Ames Ave <br /> Milpitas,CA 95035 Date Received: Oct-05-09 <br /> Job Site/ Forward Landfill <br /> No_ Total Samples Analyzed: 6 <br /> CLIENT SAMPLE# �® C3 SAMPLE LOCATION <br /> Laboratory Sample# 1199-00009-003 <br /> AIR FILTER DATA AIR PUMP DATA <br /> Type MCE 0.45um Time(min) <br /> Diameter(mm) 25 Flow Rate(Ipm) <br /> Area(sq mm) 385 Volume(liters) 862.1 <br /> CALCULATED ASBESTOS <br /> IDENTIFIED STRUCTURES STRUCTURE CONCENTRATION <br /> ASBESTOS OTHER Per CC Air Per so m <br /> C YS. AP AMB1Ci. NON-ASB. <Sum >Sum TOTAL Filter <br /> L= ND_ j ND >< < 0.0011 =000 1 EEI < <br /> COMMENTS <br /> No Asbestos Detected FILTER LOADING: MODERATE <br /> SAED PHOTO ID#'s. <br /> TEM/ANALYTICAL PARAMETERS <br /> Magnification: 15,000X ANALYTICAL SENSITIVITY <br /> Grid Openings Scanned 40 Structures/sq mm 2.5 <br /> Grid Opening Area(sq.mm.) 0.0099 Structures/cc 00011 <br /> Scan Area(sq.mm_) 0.4 <br /> NOTATION KEY <br /> Chrys.-Chrysotile Asbestos ND-None Detected <br /> Antph.-Amphibole Asbestos 1 um= I micron=0.001 mm ANALYST SIGNATURE <br /> Ambig.-Ambiguous ID I mm= 1 millimeter <br /> Non-Asb.-Non-Asbestos 1 cc= 1 cubic centimeter <br /> 1 sq.mm= I square millimeter <br /> ASBESTOS TEM LABORATORIES,INC. 630 BANCROFT WAY,BERKELEY, CA 94710 (510)7048930 <br /> www.asbestostemiabs.com Wiih Offices in Reno. NV(7 75)359-3377 <br />