Laserfiche WebLink
TRANSMISSION ELECTRON MICROSCOPY <br /> ANALYTICAL REPORT <br /> AHERA Analysis Method <br /> Contact: Bill Johnston Report No.: 072661 <br /> Address: Shaw Environmental&Infrastructure <br /> 2880 Zanker Road,Suite 101 Date: Oct-19 00 <br /> San Jose,CA 95134 Date Received: Oct-06-08 <br /> Job Site/ Forward Land Fill <br /> No. Not listed on CoC Total Samples Analyzed: 5 <br /> CLIENT SAMPLE # 1 5 SAMPLE LOCATION <br /> Laboratory Sample# 1 1199-00007-005 <br /> AIR FILTER DATA AIR PUMP DATA <br /> Type MCE 0.45u111 Time(min) 480 <br /> Diameter(min) 25 Flow Rate(Ipm) <br /> .Area(sq nun) 385 Volume(liters) 978 <br /> CALCULATED ASBESTOS <br /> IDENTIFIED STRUCTURES STRUCTURE CONCENTRATION <br /> ASBESTOS OTHER Per CC Air Per sg mm <br /> CHRYS. I AMPH. AMBIG. I NON-ASB. <5um >5um r TOTAL Filter <br /> ND ND N D 6 < 0.0010 < 0.0010 !E001fllk <br /> 2.7 <br /> COMMENTS <br /> No Asbestos Detected FILTER LOADING: MODERATE <br /> SAED PHOTO ID#'S- <br /> TEM/ANALYTICAL PARAMETERS <br /> Magnification: 18,00ox ANALYTICAL SENSITIVITY <br /> Grid Openings Scanned 40 Structures/sq mnt 2.7 <br /> Grid Opening Area(sq.mm.) 0.0094 Structures/cc 0.0010 <br /> Scan Area(sq.mm.) 0.38 <br /> NOTATION KEY <br /> r' <br /> Chrys.-Chrysotile Asbestos ND-None Detected f t ^ <br /> Amph.-Amphibole Asbestos I um= I micron=0.001 min ANALYST SIGNATURE <br /> Ambig.-Ambiguous ID I mm= I millimeter JCC �/ <br /> Non-Asb.-Non-Asbestos 1 cc= I cubic centimeter <br /> 1 sq.mm= 1 square millimeter LAB QC REVIEWER SIGNATURE <br /> ASBESTOS TEM LABORATORIES,INC. 630 BANCROFT WAY,BERKELEY, CA 94710 (510)704-8930 <br /> www.asbestostemlabs.com With Offices in Reno, MVV(775)359-3377 <br />