Laserfiche WebLink
® to be representative of the water quality conditions measured at the site. Based on the <br /> results of the laboratory QA/QC analyses,it is concluded that the laboratory data <br /> generated for the third quarter 2008 monitoring period are generally acceptable and the <br /> water quality samples collected from the Forward Unit appear to be representative of <br /> water quality at the site. <br /> 2.1.3 Groundwater Elevations and Contours <br /> Prior to purging and sampling, each well was sounded for water depth using a weighted <br /> electronic sounder to an accuracy of 0.01 foot, and the static water level was recorded on <br /> a Well Data Sheet(Appendix Q. The groundwater elevations were calculated for each <br /> well by subtracting the depth-to-water measurement from the top-of-casing reference <br /> elevation. The current groundwater elevation data for the Forward Unit is summarized in <br /> Table 2-3. <br /> The groundwater elevation data obtained during the third quarter 2008 monitoring period <br /> were used to generate the groundwater elevation contour map shown on Figure <br /> 2-1, which indicates that groundwater generally flows to the north-northeast towards the <br /> Austin Unit, at an average hydraulic gradient of approximately 0.001 ft/ft. <br /> To calculate the approximate linear groundwater flow velocity for the site, conservative <br /> assumptions were used, including a hydraulic conductivity of 875 gallons per day per <br /> AOL square foot(0.04 sec) and an estimated effective porosity of 35 percent(CH2M Hill <br /> qW 2000). An estimated groundwater flow velocity was calculated using Darcy's Law: <br /> Ki cm 0.001 sec– ft <br /> V = — = [(0.04 —)* ]* 2835 0.324 ft /day <br /> ne sec 0.35 cm – day <br /> where: V=Groundwater flow velocity. <br /> K=Hydraulic conductivity of the water-bearing unit(0.04 cm/sec). <br /> i=Hydraulic gradient: i t--0.001 for the site during the third quarter 2008. <br /> ne=Effective porosity(n,=0.35);an estimated value. <br /> The groundwater flow rate is calculated to be 0.324 feet/day(118 feet/year). <br /> 2.1.4 Detection Monitoring Program <br /> Field and laboratory results for the groundwater monitoring wells for the third quarter <br /> 2008 are summarized in Table 2-2 and Appendix D presents time-series charts of select <br /> parameters. As shown on Table 2-2, estimated trace concentrations(between the method <br /> detection limit [MDL] and the practical quantitation limit [PQL])of 1,1-dichloroethane <br /> (1,1-DCA), acetone, dichlorodifluoromethane(DCDFM), tetrachloroethene(PCE), and <br /> trichloroethene(TCE)were measured in the sample collected from wells MW-10; a trace <br /> concentration of bromoform was measured in the sample collected from well MW-13; a <br /> trace concentration of trichlorofluoromethane (TCFM)was measured in samples <br /> collected from wells MW-15 and MW-16; and a trace concentration of bis(2- <br /> D:X2008 00101FA 3Q08.doc <br /> 5 Geologic Associates <br />