Laserfiche WebLink
STATE OF CALIFORNIA California Integrated Waste <br /> CIWMB 03 (Rev. 4/04) Management Board <br /> _IPECTION REPORT ADDENDUM PAGE 3 OF 4 <br /> AGENCY CONDUCTING INSPECTION: San Joaquin County Environmental Health Department <br /> SITE NUMBER: 39-AA-0015 INSPECTOR: Robert McClelion <br /> SITE NAME: Forward Inc. <br /> RECEIVED BY <br /> INSPECTION DATE: 10/31/08 OPERATOR "A ew;"� <br /> • f <br /> COMMENTS: <br /> 1. Violation T27CCR 20690—Alternative Daily Cover(ADC)—The previous working face was covered using tarps. The tarps <br /> were not properly weighted.The winds from the passing storm removed the tarps and the site did not have cover. <br /> The tarps must be properly weighted in order to withstand anticipated winds.Immediately begin to weight the tarps <br /> to ensure that they will stay in place. <br /> 2.AC PRC 44014(b)—Terms and Conditions of the Permit—The site had a large amount of Treated Auto Shredder Waste <br /> 0 (TASW)exposed during the last storm event.The Solid Waste Facility Permit(SWFP)restricts use of TASW <br /> during times of wet weather(see LEA Conditions 17.r.). <br /> 3 AC T27CCR 20686—Beneficial Reuse—The green waste pile in the green waste grinding are had the following issues: <br /> • Temperature @ 185 degrees F.Maintain green waste temperatures below 170 degrees F. <br /> • Treated Wood Waste(TWW)found in pile.Properly remove all TWW prior to grinding. <br /> ® Oil filters from servicing grinder disposed of in green waste pile.This issue has been referred to <br /> the Hazardous Waste Unit for follow up. <br /> 4 AC T27CCR 21780—Submittal Closure Plans—The SWF•P was recently subject to a 5 year permit review.During the <br /> review it was noted that the Partial Final Closure Plan for Stage lA included information that needs to be made part <br /> of the Preliminary Closure Post Closure Plan(PCPCP)for the facility.The proposed amendment to the PCPCP has <br /> not been received by the Environmental Health Department(EHD).Provide by December 23,2008.. <br /> 5 AC T27CCR 20939(b) (1)—Sub-surface Landfill Gas Control Systems—The facility has experienced 4 subsurface <br /> landfill fires. Three of the fire occurred in this year. The fires are all located along the toe of the slope. The affected <br /> area is immediately adjacent to the horizontal collector.It appears that the landfill gas system is over pulling and <br /> creating fires to erupt below the surface of the landfill. You are directed to submit a plan to the EHD outlining how <br /> the facility operator will prevent additional fires from occurring. Submit the plan by December 1,2008. <br /> 6. Notes: <br /> A. The active working face is located in the FU-05. The cover used was TASW,PGM,soil and tarps.The site was <br /> using one large working face.The MSW and special waste(soil,bottom ash and treated wood)were using the same <br /> worldng face they were accessing it different.angles. <br /> B. The facility began to place waste in the new cell. <br /> C. The perimeter gas migration,wells were monitored during the routine inspection.The results are as follows: <br /> GP 9 (s)0.0%CH4 GP 11 (s)0.0%CH4 GP 12 (s)0.0%CH4 <br /> (i)0.0%CH4 (i)0.0% CH4 (i) 0.0%CH4 <br /> (d)0.0%CH4- (d)0.1%CH4 (d) 0.2%CH4 <br /> INSPECTOR SIGNATURE:, tl.., � DATE: It 124A _ <br />