Laserfiche WebLink
In the case of the nondedicated pump, it is lowered into the well and then activate <br /> (polder from i <br /> 'the controller box s regulated which controls the discharge rate of the h. <br /> centrifugal purge pump). In the case of a well with a dedicated'pump, the pneumatic <br /> controller box is connected to the dedimted pump (some wells have special high-rate <br /> Purge pumps used only for puigiiig, these can be identified by the fittings on the cap). A <br /> dedicated.discharge tube (kept locked at the well head in a protective •bag) is then <br /> attached to the discharge fitting on the casing cap. The-Controller is then turned on and <br /> adjusted to reach the desired purge rate. <br /> Note: In all cases where gasoline powered generator or i:ompressors are used, they are to <br /> be placed at Ieast ten feet downwind of the well being sampled. <br /> S• During purging, field parameters (pH, electrical conductivity, turbidity, and temperature) <br /> v'U be monitored. Parameter measurements will be ra:orded on Purge and Sample Logs_ <br /> In addition field observations also will be ma&and m-corded. <br /> On the Purge and Sample- <br /> Logs. Such observations include•flow rates;-vatume•purgcd;,color,odor,bubbling or-a4y-- <br /> other notable observations. An example of a Purge Charactezi on and Sample Log is <br /> attached. <br /> Purging will:continue until stable parameter readings are Obtained.. pH is considered - <br /> stable if the readings donut wary by greater than 0.1 pH unit ?Temperature is considered <br /> stable if it does not vary by mom that one degree Celsius. Conductivity and turbidity are <br /> considered stable if they do not vary by greater than M/a. Field parameters.will be <br /> repeated at approximate five gallon intex-a . A minimum of three well volumes of water - <br /> WM be removed from each well. The final,stable,valueswill be recorded to be used in <br /> the annual rccpott. . <br /> Samlile Collection = <br /> Samples will be collected as soon as possible after purging is complcted. Laboratory <br /> -supplicd <br /> contUnars will be used to hold the.water samples. Samples to be atialyied for volatile-organic <br /> constittic=will be collected first, Depending on.the well, samples Will be collet-ted-with either <br /> dedicated pumps or disposable hers (a new factory wrapped bailer will beused at each well). <br /> la the. case of dedicated pumps, the pump rate will be adjusted so that the sample will not be <br /> agitated as it is collected In sample bottles. When bailers arc used, they will be Iow+ered slowly <br /> into the wi:I1 so not to disturb the water. The sample will be decanted into the bottles slowly with - <br /> 23-433$44-FOIW I ORM A-8 July 14.20M <br /> 2"rJeb al lac. <br />