Laserfiche WebLink
submitted and analyzed within the required holding times during the fourth quarter 2009. <br /> Review of the historical TDS concentrations indicates that the concentration measured in <br /> well AMW-12 during the current monitoring period is within the range of values <br /> measured for this well. Based on the results of the laboratory blank and duplicate <br /> analyses, it is concluded that generally acceptable QA/QC procedures were exercised and <br /> the water quality samples collected from the Austin Unit appear to be representative of <br /> water quality at the site. <br /> 3.1.3 Groundwater Elevations and Contours <br /> Prior to purging and sampling, each well was sounded for water depth using a weighted <br /> electronic sounder, and the static water level was recorded on a well data sheet <br /> (Appendix C). The groundwater elevations were calculated for each well by subtracting <br /> the depth-to-water measurement from the top-of-casing reference elevation. The current <br /> groundwater elevation data for the Austin Unit are summarized in Table 3-4. <br /> The groundwater elevation data obtained during this quarterly monitoring period were <br /> used to generate the groundwater elevation contour map shown on Figure 3-1, which <br /> indicates that groundwater beneath the Austin Unit generally flows to the north-northwest <br /> at an average hydraulic gradient of approximately 0.00 15 ft/ft. <br /> To calculate the approximate linear groundwater flow velocity for the site, conservative <br /> assumptions were used, including a hydraulic conductivity of 875 gallons per day per <br /> square foot(0.04 cm/sec) and an estimated effective porosity of 35 percent (CH2M Hill <br /> 2000). An estimated groundwater flow velocity was calculated using Darcy's Law: <br /> Ki CM 0.0015 sec- ft <br /> V [(0.04 —)*—]*2835 —� 0.49 ft/day <br /> ne sec 0.35 cm - day <br /> where: V=Groundwater flow velocity. <br /> K=Hydraulic conductivity of the water-bearing unit(0.04 cm/sec). <br /> i=Hydraulic gradient: i�0.0015 for the site during the current the fourth quarter 2009. <br /> n,=Effective porosity(n,=0.35);an estimated value. <br /> The groundwater flow rate is calculated to be 0.49 feet/day(177 feet/year). <br /> 3.1.4 Detection Monitoring Program <br /> Field and laboratory results for the DMP wells for the fourth quarter 2009 are <br /> summarized in Table 3-1. As shown in Table 3-1, DCDFM was measured above the <br /> PQL, and a trace concentration of 1,2-dichloropropane was measured in the sample <br /> collected from well AMW-14; 1,1-DCA, DCDFM, and cis-1,2-DCE were measured at <br /> trace concentrations in the sample collected from well AMW-13; PCE was measured at a <br /> trace concentration in the sample collected from well AMW-6; PCE and TCE were <br /> measured above the PQL and TCFM was measured at trace concentrations in the samples <br /> collected from wells AMW-13 and AMW-14. <br /> D:\2009_0017TA_4Q09.doc <br /> 9 Geologic Associates <br />