TRANSMISSION ELECTRON MICROSCOPY <br /> ANALYTICAL PORT <br /> AHERA Analysis Method <br /> Contact: Bill Johnston Report No.: 079905 <br /> Address: Shaw Environmental&Infrastructure <br /> Date: Oct-18-09 <br /> 767 Ames Ave <br /> Milpitas,CA 95035 Date Received: <br /> Oct-OS-09 <br /> Job Site/ Forward Landfill <br /> No. Total Samples Analyzed: 6 <br /> CLIENT SAMPLE# CI SAMPLE LOCATION <br /> Laboratory Sample# 1199-00009-001 <br /> AIR FILTER DATA AIR PUMP DATA <br /> Type MCE 0.45um Time(min) <br /> Diameter(mm) 25 Flow Rate(Ipin) <br /> Area(sq mm) 385 Volume(liters) 846.7 <br /> CALCULATED ASBESTOS <br /> IDENTIFIED STRUCTURES STRUCTURE CONCENTRATION <br /> ASBESTOS OTHER Per CC Air Per sg mm <br /> CHRYS. AMPH. AMBIG. NON-ASB. <5um I >Sum TOTAL Filter <br /> ND ND ND ND < 0.0011 < 0.0011 1 <br /> COMMENTS <br /> No Asbestos Detected FILTER LOADING: MODERATE <br /> SAED PHOTO ID Xs. <br /> TEM/ANALYTICAL PARAMETERS <br /> Magnification: 15,000X ANALYTICAL SENSITIVITY <br /> Grid Openings Scanned 40 Structures/sq mm 2.5 <br /> Grid Opening Area(sq.mm.) 0.0099 Structures/cc 0-0011 <br /> Scan Area(sq.mm.) 0.4 <br /> NOTATION KEY s m <br /> Chrys.-Chrysotile Asbestos ND-None Detected <br /> Amph.-Amphibole Asbestos I um= I micron=0.001 mm ANALYST SIGNATURE <br /> Ambig.-Ambiguous ID I mm= I millimeter <br /> Non-Asb. -Non-Asbestos I cc= I cubic centimeter <br /> I sq.mm= I square millimeter <br /> ASBESTOS TEM LABORATORIES,INC. 630 BANCROFT WAY,BERKELEY, CA 94710 (510)704-8930 <br /> www.asbestostemiabs.com With Offices in Reno, .VV(775)359-3377 <br />