My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_2009_19
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
4400 - Solid Waste Program
>
PR0440005
>
Archived Reports
>
ARCHIVED REPORTS_2009_19
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2020 3:53:32 PM
Creation date
7/3/2020 10:54:58 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
2009_19
RECORD_ID
PR0440005
PE
4433
FACILITY_ID
FA0004516
FACILITY_NAME
FORWARD DISPOSAL SITE
STREET_NUMBER
9999
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20106001-3, 5
CURRENT_STATUS
01
SITE_LOCATION
9999 AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440005_9999 AUSTIN_2009_19.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
60
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ASBESTOS by TEM: METHOD 7402, Issue 2, dated 15 August 1994-Page 7 of 7 <br /> CALCULATIONS: <br /> 21. Calculate and report the fraction of optically visible asbestos fibers on the fitter, <br /> (fs -ft,)/(Fs - Fb). Apply this fraction to fiber counts obtained by PCM on the same filter or on other <br /> filters for which the TEM sample is representative. The final result is an asbestos fiber count. The <br /> type of asbestos present should also be reported. <br /> 22. As an integral part of the report, give the model and manufacturer of the TEM as well as the model <br /> and manufacturer of the EDX system. <br /> EVALUATION OF METHOD: <br /> The TEM method, using the direct count of asbestos fibers, has been shown to have a precision of <br /> 0.275 (s,) in an evaluation of mixed amosite and wollastonite fibers. The estimate of the asbestos <br /> fraction, however, had a precision of 0.11 (s �). When this fraction was applied to the PCM count, the <br /> overall precision of the combined analysis was 0.20[2]. <br /> REFERENCES: <br /> [1] Walton,W. H. "The Nature, Hazards, and Assessment of Occupational Exposure to Airborne <br /> Asbestos Dust: A Review," Ann. Occup. Hyg., 25, 115-247 (1982). <br /> [2] Taylor, D. G., P. A. Baron, S. A. Shulman and J_ W. Carter. "Identification and Counting of <br /> Asbestos Fibers," Am. Ind. Hyg. Assoc. J. 45(2), 84-88(1984). <br /> [3] Johnston,A. M., A. D. Jones, and J. H_ Vincent. 'The Influence of External Aerodynamic Factors <br /> on the Measurement of the Airborne Concentration of Asbestos Fibers by the Membrane Filter <br /> Method," Ann. Occup. HvQ_ 25, 309-316 (1982). <br /> [4] Zumwalde, R. O. and J. M_ Dement. Review and Evaluation of Analytical Methods for <br /> Environmental Studies of Fibrous Particulate Exposures, NIOSH Technical Information Bulletin <br /> #77-204 (1977). <br /> [5] Baron, P. A. and G. C. Pickford. "An Asbestos Sample Filter Clearing Procedure," AS I. L— Hvo., <br /> 1:169-171,199 (1986)- <br /> [6] LeGuen, J. M. and S. Galvin "Clearing and Mounting Techniques for the Evaluation of Asbestos <br /> Fibers by the Membrane Filter Method" Ann. Occup. Hyg. 24, 273-280 (1981)- <br /> [71 Yamate, G., S. A. Agarwal, and R. D. Gibbons. "Methodology for the Measurement of Airborne <br /> Asbestos by Electron Microscopy,"EPA Contract No. 68-02-3266 (in press). <br /> [8] Steel, E. B. and J. A. Small. "Accuracy of Transmission Electron Microcopy for the Analysis of <br /> Asbestos in Ambient Environments;' Anal. Chem., 57, 209-213 (1985). <br /> METHOD REVISED BY: <br /> Paul A. Baron, Ph.D.; NIOSH/DPSE. <br /> NIOSH Manual of Analytical Methods(NMAM),Fourth Edition, 8/15/94 <br />
The URL can be used to link to this page
Your browser does not support the video tag.