Laserfiche WebLink
Ca[Recoe <br /> Disposal Facility Inspection Report (52) <br /> ntrce11county of San Joaquin <br /> ,,,. ,erfrc3xa <br /> s111acHi1 <br /> MINE 1p <br /> -�? sa^ram wasu.min.. :. a <br /> 39-AA-0015 4/23/2010 LEA Periodic <br /> y <br /> RS m <br /> Tame r� <br /> Forward Landfill,Inc. Forward, Inc./Allied Waste North America <br /> 9999 S.Austin Road, Manteca 95336 <br /> �per: -,- <br /> Robert McClellon <br /> THEAOMFACBlI MSNSPWMFCR iMW"APPLCAMESEMMOFTxeomMm+30DFlMPKU Caesol CEs�El luro rrtLE unNo mLEacurvl8+we�Eoc (mow <br /> �- <br /> Yegala'f <br /> IM20580- Lighting <br /> Comments:The site is using light towers to provide additonal lighting for the site during the early morning hours. <br /> The light towers must be placed either facing West or North.This month as well as last month the towers were <br /> facing South and East, respectively. The direction of the lighting is crucial to reducing confusion to pilots landing <br /> at the Stockton Metropolitan Airport. Corret immediately. <br /> x 20820- Drainage/Erosion Control <br /> Comments: The site is subject to ponding on the top deck of FU 03, 04, 05. The site also has ponding on the. <br /> North slope, in closed area stage 1 a,on or near the bench. There was a large amount of ponding on the top <br /> deck of the old Austin road site East of the acrtve fill areas. In some areas the water was as deep as 12 inches. <br /> There was additional ponding on the old Forward site along the access road.This was listed as an area of <br /> concern on 2 previous inspection reports. Properly grade these areas to promote lateral run off.This item will be <br /> checked on the next inspection for the site. <br /> There was erosion on the South slope of FU 03. Properly repair the slope when weather and conditions permit. <br /> X 20921 - Gas Monitoring and Control <br /> Comments:The perimeter gas probes were monitored during the inspection.The following was the result. <br /> GW11 (s)0.0%CH4 (1)3.5%CH4 (d)0.0% CH4 <br /> GW12(s)2.7% CH4(1) 1.3%CH4 (d)0.0% CH4 <br /> The gas levels are trending lower.The operator has made some changes to the gas system.The EHD has seen <br /> the 6 inch lateral that has been added. Details regarding the changes are not clear.The EHD is waitng for <br /> additonal information from the operator. <br /> rispec'!ab pnromme - <br /> A Routine inspection was conducted this date and the followin was noted: <br /> 1.The transfer trucks are not cleaning out the beds or retarping the trailer so that litter is not blown out of the truack when <br /> they leave the site. Inform the trucking firms using the site and make sure they are aware of the requirement. <br />