My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_2010_13
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
4400 - Solid Waste Program
>
PR0440005
>
Archived Reports
>
ARCHIVED REPORTS_2010_13
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2020 3:53:35 PM
Creation date
7/3/2020 10:55:17 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
2010_13
RECORD_ID
PR0440005
PE
4433
FACILITY_ID
FA0004516
FACILITY_NAME
FORWARD DISPOSAL SITE
STREET_NUMBER
9999
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20106001-3, 5
CURRENT_STATUS
01
SITE_LOCATION
9999 AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440005_9999 AUSTIN_2010_13.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
210
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Sampling Equipment <br /> Inter7rn gas sampltng probes were used to monitor subsmficegases at the landfill <br /> Bach probe cons' of a S-f t to Yrinch d' Iterpe, with Perimeter. <br /> d 2 inches at Clic bottom 18 inches to allow for ess steel P= %-inch holes <br /> es to into the probes. A <br /> pointed tip was welded to +end of the probe for better etration'. <br /> A ball valve and biass fitdng.wm installed at the top of each probe to contain gas <br /> pressures and <br /> facilitate <br /> instrurnauhook-up to the probe.The valves were left closed c7cc t during monitoring <br /> or °msumment reading.Each probe is tagged with a brass plate and identified as "OP-1" through <br /> AGA-90 Landtec -red-Gas Analyzer was used to monitor methane. caeocm diode.(CO.), <br /> and oxygen(O,}levels at each probe location_The analyzer was calibrated for methane,COX,and <br /> 02 prior to use in the field_Calibration.logs are.included.in dfmreport. <br /> Gas.MonitoringArn - <br /> blent air measuremeras of methane, oxygen, carbon dioxides and barometric - <br /> taken at each were 4 <br /> gas be location. These readings were recorded and-the ' cw> was •4conn ` <br /> ected to the probe. 'The valve was opened and probe.gas pressummeasurements were taken. <br /> probe was than. purged for- two. probe volumes. Rcadirtgs'vtere thea tollat <br /> y 34- to nd iint :u uW..a Stable. . <br /> reading was .o • ed. <br /> m ants of madigrieoxygen, carbon diax ide, and ambient barometric pressure wee then <br /> - <br /> rde d- Monitoring was also conducted at various locations in building site for the <br /> presence of mediane.gas. Monitoring was conducted at the office trailer at the entrance to the <br /> trailer boxes- at the service shop, aiid trailer boxes at the transfer bxtikhng. 'These <br /> locat'ons were MQWWr4Cd for any gas packeU at the foundation and near any opening from the <br /> Boor 54ch as piping holes,electrical conduits,or Iloor cracks. <br /> LYSOAETERS <br /> Lysimct=were sampled using the following staridard protocol: <br /> 1. Prior to sampling lysimeters,the p vacuum equipment is checked and cleaned. <br /> 849--FA t1731oRM A-12 <br /> der.kr fitly 14,2000 <br />
The URL can be used to link to this page
Your browser does not support the video tag.