Laserfiche WebLink
Product Specification - Structural Geogrid UX800HS <br /> Tensar Earth Technologies,inc.reserves the right to change its product specifications at anytime. It is the <br /> ensure that product specifications used for design and procurement with <br /> the <br /> odd of the d in each <br /> and purchaser to <br /> Purposes are current and consistent with the products used In each fnsta <br /> contact Tensar Earth Technologies,ink.at 800-836-7271 for assistance nce. Please <br /> The structural geogrid shall be an integrally formed grid structure manufactured of a stress resistant polypropylene material with molecular <br /> weight and molecular characteristics which impart:(a)high resistance to loss of load capacity or structural integrity when the geogrid is <br /> subjected to mechanical stress in installation;(b)high resistance to deformation when the geogrid is subjected to applied force in use;and <br /> (c)high resistance to loss of load capacity or structural integrity when the geogrid is subjected to long-term environmental stress. <br /> The structural geogrid shall accept applied force in use by positive mechanical interlock(i.e.by direct mechanical keying)with:(a) <br /> compacted soil or construction fill materials;(b)contiguous sections of itself when overlapped and embedded in compacted soil or <br /> construction fill materials;and(c)rigid mechanical connectors such as bodkins,pins or hooks.The structurat geogrid shall possess <br /> sufficient cross sectional profile to present a substantial abutment interface to compacted soil or particulate construction flit materials and <br /> to resist movement relative to such materials when subject to appried force. The structural geogrid shall possess sufficient true initial <br /> lied force to be transferred to the geogrid at low strain levels without material deformation of the reinforced structure. <br /> modulus to cause app <br /> The structural geogrid shall possess complete continuity of all properties throughout its structure and shag be suitable for reinforcement of <br /> compacted soil or particulate construction fill materials to improve their long term stability in structural load bearing applications such as <br /> earth retention systems. The structural geogrid shall otherwise have the following characteristics: <br /> Product Type: Integrally Formed Structural Geogrid <br /> Load Transfer Mechanism: Positive Mechanical Interlock <br /> Product Properties <br /> Load Capacity Units <br /> MD Values <br /> • True initial Modulus in Use Mm(lb✓ft) 800(54,830) <br /> • Tensile Strength @5%Strain kN/m(Ib/ft) 25(1,710) <br /> • Ultimate Tensile Strength2 kN/m(It>/ft) 50(3,430) <br /> • Long-Term Allowable Load in Sands.Silts&Clay3 kN/m b/ft <br /> ) 12.5(860) <br /> • Long-Term Allowable Load in Weil Graded Sandi kN/m(tb/ft) 12.2 830 <br /> • Long-Term Allowable Load in Aggregate3 kN/m t ( ) <br /> (b/ft) 12.0(820) <br /> integrity of Product Structure <br /> • Junction Strength° kN/m(lb/ft) 47(3,180) <br /> • Flexural Stiffnesss X1000 mg-cm 500 <br /> Durability <br /> • Resistance to installation Damageii %SC/%SW/%GP <br /> • Resistance to Long Term Degradations • 95/92/90 <br /> � 100 <br /> Dimensions and Delivery <br /> The structural geogrid shalt be delivered to the jobsite in roll form with each roll individually identified and nominally measuring 1.33 <br /> meters(4.36 feet)in width and 76.2 meters(250.0 feet)in length. A typical truckload quantity is 324 rolls. On special request,the <br /> structural geogrid may also be custom cut to specific lengths or widths to suit site specific engineering designs. <br /> Notes <br /> 1.Unless indicated otherwise,values shown are minimum average.roil values determined in accordance with ASTM D-4759grief descriptions of test <br /> procedures are given in the following notes. Complete descriptions of test procedures are available on request from Tensar Earth Technologies, <br /> Inc. <br /> 2.True resistance to elongation when initially subjected to a bad measured via ASTM D6637 without deforming test materials under load before <br /> measuring such resistance or employing"secant'or"offset"tangent methods of measurement so as to overstate tensile properties. <br /> 3.True strength available for resisting force in brig-term load bearing applications is determined by reducing ultimate tensile strength by state-of- <br /> practice factors for installation damage,degradation in use,product integrity limitations and long-term product deformation per GRI-GG4. <br /> 4.Load transfer capability measured via GRI-GG2-87. <br /> 5.Resistance to bending force measured via ASTM D-5732-95,using specimen dimensions of 864 millimeters in length by 1 aperture in width. <br /> 6.Resistance to loss of load capacity or structural integrity when subjected to mechanical installation stress in clayey sand(SC),well graded sand <br /> (SW),and crushed stone classified as poorly graded gravel(GP).The material shalt be sampled in ac.cordance with ASTM D5818 and load capacity <br /> measured in accordance with ASTM D6637. <br /> 7.Resistance to lass of load capacity or structural integrity when subjected to chemically aggressive environments measured via EPA 9090 immersion <br /> testing. <br /> Tensar Earth Technologies,Inc. <br /> 5883 Glenridge Drive,Suite 200 <br /> Atlanta,Georgia 30328-5363 <br /> (800)836-7271 <br /> February 1,2004 <br /> This product specification supersedes all prior specifications for the product described above and is not applicable to any products shipped prior to <br /> February 1.2004. <br />