My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_2010_14
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
4400 - Solid Waste Program
>
PR0440005
>
Archived Reports
>
ARCHIVED REPORTS_2010_14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/18/2020 12:56:45 AM
Creation date
7/3/2020 10:55:19 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
2010_14
RECORD_ID
PR0440005
PE
4433
FACILITY_ID
FA0004516
FACILITY_NAME
FORWARD DISPOSAL SITE
STREET_NUMBER
9999
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20106001-3, 5
CURRENT_STATUS
01
SITE_LOCATION
9999 AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440005_9999 AUSTIN_2010_14.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
415
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Product Specification - Structural Geogrid UX11OOHS <br /> Tensar Earth Technologies,Inc reserves the right to change its product specifications at any time. It Is the responsibility <br /> ensure that product sperm �s�are cations used for desf and Procurement u the pdurooddcts used in each instance. Please <br /> of the specifier and purchaser to <br /> contact Tensar Earth Technologies,Inc.at 8'00-836.7271 for assistance <br /> and consistent with <br /> The structural geogrid shalt be an integrally formed grid structure manufactured of a stress resistant high density polyethylene material <br /> with molecular weight and molecular characteristics which impart:(a)high resistance to loss of bad capacity or structural integrity when <br /> the geogrid is subjected to mechanical stress in installation;(b)high resistance to deformation when the geogrid is subjected to applied <br /> force ih use;and(c)high resistance to loss of load capacity or structural integrity when the geogrid is subjected to long-term <br /> environmental stress. <br /> The structural geogrid shalt accept applied force in use by positive mechanical interlock(ii.e.by direct mechanical keying)with:(a) <br /> compacted soil or construction fill materials;(b)contiguous sections of itself when overlapped and embedded in compacted soil or <br /> construction fill materials;and(c)rigid mechanical connectors such as bodkins,pins or hooks.The structural geogrid shall possess <br /> sufficient cross sectional profile to present a substantial abutment interface to compacted soil or particulate construction fill materials and <br /> to resist movement relative to such materials when subject to applied force. The structural geogrid shall possess sufficient true initial <br /> modulus to cause applied force to be transferred to the geogrid at low strain levels without material deformation of the reinforced structure. <br /> The structural geogrid shall possess complete continuity of all properties throughout its structure and shall be suitable for reinforcement of <br /> compacted soil or particulate construction fill materials to improve their long term stability in structural load bearing applications such as <br /> earth retention systems. The structural geogrid shall otherwise have the following characteristics: <br /> Product Type: Integrally Formed Structural Geogrid <br /> Load Transfer Mechanism: Positive Mechanical interlock <br /> Product Properties <br /> Load Capacity Units MD Values' <br /> • True Initial Modulus in Use' kN/m(lb/ft) 800(54,$30) <br /> • Tensile Strength @5%Strain' kN/m(lb/ft) 27(1,850) <br /> • Ultimate Tensile Strength' kN/m(lb/ft) 58(3,970) <br /> • Long-Term Allowable Load in Sands,Silts&Clay3 kN/m(lb/ft) 23.6(1,620) <br /> • Long-Term Allowable Load in Well Graded Sandi kN/m(lb/ft) 23.0(1,570) <br /> • Long-Term Allowable Load in Aggregate kN/m(lb/ft) 22.6(1,550) <br /> Integrity of Product Structure <br /> - Junction Strength® kN/m(Ib/ft) 54(3,690) <br /> • Flexural Stiffness X1000 mg-cm 500 <br /> Durability <br /> • Resistance to Installation Damages %SC/%SW/%GP 95192/90 <br /> - Resistance to Long Term Degradation' % 100 <br /> Dimensions and Delivery <br /> The structural geogrid shall be delivered to the jobsite in roll form with each roll individually identified and nominally measuring 1.33 <br /> meters(4.36 feet)in width and 762 meters(250.0 feet)in length. A typical truckload quantity is 324 rolls. On special request,the <br /> structural geogrid may,also be custom cut to specific lengths or widths to suit site specific engineering designs. <br /> Notes <br /> 1.unless indicated otherwise,values shown are minimum average roll values determined in accordance with ASTM D-4759. Brief descriptions of test <br /> procedures are given in the following rotes. Complete descriptions of test procedures are available on request from Tensar Earth Technologies. <br /> Inc. <br /> 2.True resistance to elongation when initially subjected to a bad measured via ASTM D6637 without defaming test materials under load before <br /> measuring such resistance or employing"secant or"offset"tangent methods of measurement so as to overstate tensile properties. <br /> 3.True strength available for resisting face in tang-term load bearing applications is determined by reducing ultimate tensile strength by state-of- <br /> practice factors for installation damage,degradation in use,product integrity limitations and long-term product deformation per GRI-GG4. <br /> 4.Load transfer capability measured via GRI-GG2-87. <br /> 5.Resistance to bending force measured via ASTM D-5732-95,using specimen dimensions of 864 millimeters in length by 1 aperture in width. <br /> 6.Resistance to loss of toad capacity or structural integrity when subjected to mechanical installation stress in clayey sand(SC),well graded sand <br /> (SW),and crushed stone classified as poorly graded gravel(GP).The material shall be sampled in accordance with ASTM D5818 and load capacity <br /> measured in accordance with ASTM D6637. <br /> 7.Resistance to loss of load capacity or structural integrity when subjected to chemically aggressive environments measured via EPA 9090 immersion <br /> testing_ <br /> Tensar Earth Technologies,Inc. <br /> 5883 Glenridge Drive,Suite 200 <br /> Atlanta,Georgia 30328-5363 <br /> (800)8364271 <br /> February 1.2004 <br /> This product specification supersedes all prior specifications for the product described above and is not applicable to any products shipped prior to <br /> February 1,2004. <br />
The URL can be used to link to this page
Your browser does not support the video tag.