Laserfiche WebLink
* * * * * DEFAULT SEGMENT LENGTH SELECTED BY XSTABL <br /> * <br /> Length of line segments for active and passive portions of <br /> sliding block is 28.0 ft <br /> Box x-left y-left x-right y-right Width <br /> no. (ft) (ft) (ft) (ft) (ft) <br /> 1 105.0 112.0 200.0 113.0 1.5 <br /> 2 201.0 113.0 700.0 118.0 1.5 <br /> Factors of safety have been calculated by the <br /> * * * * * SIMPLIFIED JANBU METHOD <br /> The 10 most critical of all the failure surfaces examined <br /> are displayed below - the most critical first <br /> Failure surface No. 1 specified by 12 coordinate points <br /> Point x-surf y-surf <br /> No. (ft) (ft) <br /> 1 104.06 114.37 <br /> 2 105.38 113.05 <br /> 3 107.03 111.40 <br /> 4 375.10 115.06 <br /> 5 375.80 115.76 <br /> 6 395.60 135.56 <br /> 7 415.40 155.36 <br /> 8 . 435.20 175.15 <br /> 9 455.00 194.95 <br /> 10 474.80 214.75 <br /> 11 494.59 234.55 <br /> 12 510.04 250.00 <br /> ** Corrected JANBU FOS = 1.577 ** (Fo factor = 1.072) <br /> Failure surface No. 2 specified by 12 coordinate points <br /> Point x-surf y-surf <br /> No. (ft) (ft) <br /> 1 117.63 118.96 <br /> 2 123.35 113.23 <br /> 3 123.74 112.85 <br /> 4 355.66 114.64 <br /> 5 356.59 115.57 <br /> 6 376.39 135.36 <br />