My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_2011_19
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
4400 - Solid Waste Program
>
PR0440005
>
Archived Reports
>
ARCHIVED REPORTS_2011_19
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2020 8:35:34 PM
Creation date
7/3/2020 10:56:15 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
2011_19
RECORD_ID
PR0440005
PE
4433
FACILITY_ID
FA0004516
FACILITY_NAME
FORWARD DISPOSAL SITE
STREET_NUMBER
9999
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20106001-3, 5
CURRENT_STATUS
01
SITE_LOCATION
9999 AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440005_9999 AUSTIN_2011_19.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
159
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
n <br />0 <br />G <br />LI <br />r <br />C <br />II <br />Control functions: <br />• Speed control in no-load and isolated operation <br />• Power output control in parallel operation system; job -specific with respect to internal and external set <br />point values. <br />• LEANOX control system for control of boost pressure; dependent upon the generator terminal power and <br />the mixture temperature via the engine -driven air -gas mixer <br />• Knocking control: adjustment of the ignition point, power output and (insofar as is locally possible) the <br />mixture temperature in the event of detection of knocking. <br />• Load sharing between several modules in isolated operation <br />• Linear reduction of power output in the event of excessive mixture temperature and ignition failures <br />• Interface relays as per the interface list <br />. Multi -transducer, to record the following electrically measured variables of the generator: <br />• Phase current (with slave pointer) <br />• Neutral conductor current <br />• Voltages Ph/Ph and Ph/N <br />• Active power (with slave pointer) <br />• Reactive power <br />• Apparent power <br />• Power factor <br />• Frequency <br />An additional 0 - 20 mA output is produced for active power, as well as a pulse output for active power <br />demand. <br />The following alternator supervisions are integrated with the multi -transducer (max. 8 functions <br />simultaneous): <br />• Overload/short-circuit [51], [50] <br />• Over voltage [59] <br />• Undervoltage [27] <br />• Asymmetric voltage [64], [59N] <br />• Unbalance current [46] <br />• Failure Exitation [40] <br />• Overfrequency [81>] <br />• Underfrequency [81 <] <br />• Lockable operation mode selector switch positions: <br />® No operation is possible, running set will shut down; <br />• "MANUAL" <br />Manual operation using (start, stop) is possible, unit is not available for fully automatic operation. <br />• "AUTOMATIC' <br />Fully automatic operation, according to remote demand signal: <br />• Automatic start <br />Fully automatic operation at full load <br />• Stop with cooling down run for 1 minute <br />Continuous operation of auxiliaries for 5 minutes after engine shutdown <br />• Demand switch with the positions: <br />• Demand OFF <br />19.04.2011/2 TS JGS616 E22 4160V April 19 2011 Ameresco Forward LFG-WES <br />21/32 <br />
The URL can be used to link to this page
Your browser does not support the video tag.