My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_2013_8
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
4400 - Solid Waste Program
>
PR0440005
>
Archived Reports
>
ARCHIVED REPORTS_2013_8
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2020 3:53:43 PM
Creation date
7/3/2020 10:57:25 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
2013_8
RECORD_ID
PR0440005
PE
4433
FACILITY_ID
FA0004516
FACILITY_NAME
FORWARD DISPOSAL SITE
STREET_NUMBER
9999
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20106001-3, 5
CURRENT_STATUS
01
SITE_LOCATION
9999 AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440005_9999 AUSTIN_2013_8.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
358
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
® STABILITY ANALYSIS <br /> WMU FU-13,FORWARD LANDFILL <br /> PROBLEM: <br /> Assess the static stability of the refuse over the base and side slope lining system for WMU FU-13 at the <br /> Forward Landfill. Because WMU FU-13 is an interior module,there are no slope on this module that will <br /> coincide with the final landfill grades. Seismic analyses are,therefore,not required. <br /> GIVEN: <br /> These calculations have been previously performed for the prior WMUs at the site and they have been <br /> found to have a satisfactory factor of safety and seismic deformation. The analysis for WMU FU-13 is <br /> similar to WMUs FU-03,ART-03,FU-04,FU-05,FU-06,FU-08,FU-10 and various other WMUs at the <br /> site. <br /> SUMMARY: <br /> 1. The planned maximum elevation of refuse in WMU FU-13,prior to the development of adjacent <br /> waste management units,is 150 ft MSL.This elevation is based on 3:1 slopes on the south and east. <br /> The west slope is filled against an existing refuse slope. The north slope is filled against the southern <br /> slope of the former Austin Road Landfill. <br /> 2. Development is planned to the east and south of WMU FU-13. These slopes are,therefore,temporary <br /> and will eventually be buttressed by adjacent slopes. <br /> STABILITY ANALYSIS SECTIONS AND CRITERIA: <br /> 1. The critical cross section for the stability analysis under the maximum interim filling configuration <br /> (refuse fill elevation 150 ft)is in the NW-SE direction along the northern slope and base of the cell. <br /> 2. For interim slopes,a static factor of safety of 1.2 to 1.3 is acceptable. <br /> SUMMARY OF STABILITY ANALYSIS RESULTS <br /> 1. The minimum factor of safety for WMU FU-13 under the planned interim fill configuration(refuse <br /> elev. 150 ft)is 1.36. The critical failure surface extends from approximately the crest of refuse, <br /> through the refuse mass,and then along a portion of the base and slope liner. Both the base liner <br /> interfaces(clay/HDPE and cushion geotextile/HDPE)were analyzed but the cushion geotextile/HDPE <br /> condition was found to be more critical. <br /> 2. The stability analysis assumes the base liner interface shear strengths between the clay and textured <br /> HDPE are a friction angle of 18 degrees and an apparent cohesion of 0 psf and a friction angle of 10 <br /> degrees and an apparent cohesion of 1,000 psf for normal load ranges from 0 to 6,500 psf and from <br /> 6,500 to 17,000 psf,respectively. The base liner interface strength between the cushion geotextile and <br /> the textured HDPE geomembrane is as follows: <br /> Normal Stress(psf) Minimum Shear Stress(psf) <br /> 2,000 700 <br /> 4,000 1,110 <br /> 8,000 1,950 <br /> 12,000 2,780 <br />
The URL can be used to link to this page