My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_2013_8
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
4400 - Solid Waste Program
>
PR0440005
>
Archived Reports
>
ARCHIVED REPORTS_2013_8
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2020 3:53:43 PM
Creation date
7/3/2020 10:57:25 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
2013_8
RECORD_ID
PR0440005
PE
4433
FACILITY_ID
FA0004516
FACILITY_NAME
FORWARD DISPOSAL SITE
STREET_NUMBER
9999
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20106001-3, 5
CURRENT_STATUS
01
SITE_LOCATION
9999 AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440005_9999 AUSTIN_2013_8.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
358
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• Verify that equipment operators are fully trained and qualified to perform their work. <br /> • Verify that test equipment meets Specifications. <br /> • Verify the entire length of each seam is tested in accordance with the Specifications. <br /> • Observe all continuity testing and record results on the panel/seam log, and the panel <br /> layout drawing. <br /> • Verify that all testing is completed in accordance with the Specifications. <br /> • Identify any failed areas,by marking the area with a waterproof marker compatible with <br /> geomembrane,inform the Geosynthetics Contractor of any required repairs, and record <br /> the repair on the panel/seam log. <br /> • Verify that all repairs are completed and tested in accordance with the Specifications. <br /> • Record all completed and tested repairs on a repair sheet,and the panel layout drawing. <br /> Destructive Seam Sampling Procedures and Field Testing. Destructive seam samples will be <br /> taken at intervals of at least one test per 500 linear feet of geomembrane seams. However,additional <br /> samples will be taken if the QA/QC Inspgctor suspects that a seam does not meet the Specification <br /> requirements. Reasons for taking additional samples may include, but are not limited to: <br /> • Wrinkling in seam area <br /> • Excess crystallinity <br /> • Suspect seaming equipment or techniques <br /> • Weld contamination <br /> • Insufficient overlap <br /> • Adverse weather conditions <br /> • Failing tests <br /> The QA/QC Inspector selects the locations from where seam samples will be cut for destructive <br /> laboratory testing as follows: <br /> • A minimum of one test per 500 feet of seam length. This is an average frequency for the <br /> entire installation; individual samples may be taken at greater or lesser intervals. The <br /> testing frequency will be increased if welding operations were conducted in temperatures <br /> below 400F. This increase will be agreed upon by the Construction Manager, QA/QC <br /> Manager, and Geosynthetics Contractor. <br /> • A maximum frequency must be agreed to by the Construction Manager, QA/QC <br /> Manager,and Geosynthetics Contractor at the pre-construction meeting. However,if the <br /> Page 33 <br />
The URL can be used to link to this page
Your browser does not support the video tag.