Laserfiche WebLink
• <br />• <br />August 7, 2014 Lab ID : STK1436972 <br />Forward Inc. Customer : 3-8692 <br />Quality Control - Inorganic <br />Constituent <br />Method <br />Date/ID <br />Type <br />Units <br />Cone. <br />QC Data <br />DQO <br />Note <br />Wet Chem <br />CA ELAP Certification No, 1563 <br />Solids, Total Dissolved <br />2540 C <br />07/16/14:208265CTL <br />Blank <br />mg/kg <br />ND <br /><200 <br />LCS <br />mg/kg <br />10180 <br />100% <br />N/A <br />STK1436972-002) <br />Dup <br />m <br />3.3% <br />N/A <br />2540CE <br />07/15/14:208195CTL <br />Blank <br />mg/L <br />ND <br /><20 <br />LCS <br />mg/L <br />998.4 <br />101% <br />90-110 <br />STK1436830-005 <br />Dun <br />mg/L <br />1.3% <br />10.0 <br />Nitrate <br />300 <br />07/29/14:208731CHL <br />Blank <br />mg/kg <br />ND <br /><4 <br />LCS <br />mg/kg <br />200.0 <br />96.5% <br />85-115 <br />MS <br />mg/kg <br />394.5 <br />43.6% <br />19-212 <br />(SP 1408319-001) <br />MSD <br />mg/kg <br />396.0 <br />36.8% <br />19-212 <br />MSRPD <br />m <br />99.01 <br />0.8% <br />4_33 <br />300.0 <br />07/29/14:211289CHL <br />CCV <br />ppm <br />20.00 <br />1 01 % <br />90-110 <br />CCV <br />PPM <br />20.00 <br />t00 % <br />90-110 <br />Nitrogen, Total Kjeldahl <br />351.2 <br />07/31/14:208815jmg <br />Blank <br />mg/kg <br />ND <br /><50 <br />LCS <br />mg/kg <br />600.0 <br />99.4% <br />31-149 <br />MS <br />mg/kg <br />500.0 <br />724% <br /><'/4 <br />(CC 1482462-001) <br />MSD <br />mg/kg <br />517.2 <br />1910% <br /><'/4 <br />MSRPD <br />m <br />517.2 <br />22.1% <br />4580 <br />351.2 <br />08/04/14:208954jmg <br />Blank <br />mg/L <br />ND <br /><0.5 <br />LCS <br />mg/L <br />12.00 <br />89.5% <br />73-124 <br />MS <br />mg/L <br />12.00 <br />88.9% <br />54-136 <br />(STK1437590-002) <br />MSD <br />mg/L <br />12.00 <br />94.2% <br />54-136 <br />MSRPD <br />m <br />12.00 <br />5.8% <br />4_27 <br />Nitrate + Nitrite as N <br />450ONO3F <br />MS <br />mg/L <br />11.27 <br />93.4% <br />5-285 <br />(STK1436834-001) <br />MSD <br />mg/L <br />11.27 <br />90.6% <br />5-285 <br />MSRPD <br />mg/L <br />11.27 <br />0.8% <br />:530.4 <br />450ONO3F <br />07/15/14:210505CJJ <br />CCB <br />mg/L <br />0.013 <br />0.1 <br />CCV <br />mg/L <br />11.27 <br />95.7% <br />90-110 <br />CCB <br />mg/L <br />-0.011 <br />0.1 <br />CCV <br />mg/L <br />11.27 <br />95.1% <br />90-110 <br />OD <br />5210B <br />07/11/14:300410SRG <br />RgBlk <br />mg/L <br />0.16 <br />2 <br />LCS <br />mg/L <br />198.0 <br />94.1% <br />84.6-115 <br />(STK1436948-001) <br />Dup <br />mg/L <br />16.3% <br />15.9 <br />440 <br />STK1436948-001 <br />Dun <br />m L <br />9.7% <br />15.9 <br />5210B <br />07/16/14:300416SRG <br />CCV <br />mg/L <br />1.000 <br />97.0% <br />80-120 <br />CCV <br />mg/L <br />1.000 <br />97.0% <br />80-120 <br />5210B <br />07/18/14:208294MCA <br />RgBlk <br />mg/kg <br />0.17 <br />2 <br />LCS <br />mg/kg <br />198.0 <br />87.6% <br />84.6-115 <br />(STK1436972-005) <br />Dup <br />mg/kg <br />22.2% <br />15.9 <br />440 <br />STK1436972-005 <br />Dup <br />m <br />22.7% <br />15.9 <br />440 <br />5210B <br />07/23/14:211194amm <br />CCV <br />mg/L <br />1.000 <br />100% <br />80-120 <br />CCV <br />mg/L <br />1.000 <br />99.0 % <br />80-120 <br />Nitrogen, Total Kjeldahl <br />EPA351.2 <br />08/04/14:211487AMB <br />ICB <br />mg/L <br />0.066 <br />0.5 <br />ICV <br />mg/L <br />5.000 <br />104% <br />90-110 <br />CCB <br />mg/L <br />0.119 <br />0.5 <br />CCV <br />m L <br />5.000 <br />108 o <br />90-110 <br />EPA351.2 <br />08/07/14:211708AMB <br />CCB <br />mg/L <br />0.227 <br />0.5 <br />CCV <br />mg/L <br />5.000 <br />105% <br />90-110 <br />CCB <br />mg/L <br />0.437 <br />0.5 <br />CCV <br />m L <br />5.000 <br />94.4% <br />90-110 <br />Definition <br />ICV : Initial Calibration Verification - Analyzed to verify the instrument calibration is within criteria. <br />ICB : Initial Calibration Blank - Analyzed to verify the instrument baseline is within criteria. <br />CCV : Continuing Calibration Verification - Analyzed to verify the instrument calibration is within criteria. <br />CCB : Continuing Calibration Blank - Analyzed to verify the instrument baseline is within criteria. <br />Corporate Offices & Laboratory <br />Office & Laboratory <br />853 Corporation Street <br />2500 Stagecoach Road <br />Santa Paula, CA 93060 <br />Stockton, CA 95215 <br />TEL: (805)392-2000 <br />TEL: (209)942-0182 <br />Env FAX: (805)525-4172 /Ag FAX: (805)392-2063 FAX: (209)942-0423 <br />CA ELAP Certification No. 1573 <br />CA ELAP Certification No, 1563 <br />Office & Laboratory <br />563 E. Lindo Avenue <br />Chico, CA 95926 <br />TEL: (530)343-5818 <br />FAX: (530)343-3807 <br />CA ELAP Certification No. 2670 <br />Once & Laboratory <br />3442 Empresa Drive, Suite D <br />San Luis Obispo, CA 93401 <br />TEL: (805)783-2940 <br />FAX: (805)783-2912 <br />CA ELAP Certification No. 2775 <br />Page 9 of 10 <br />Office & Laboratory <br />9415 W Goshen Avenue <br />Visalia, CA 93291 <br />TEL: (559)734-9473 <br />FAX: (559)734-8435 <br />CA ELAP Certification No. 2810 <br />