Laserfiche WebLink
Water Quality Monitoring Report <br /> Forward Landfill <br /> 1.0 INTRODUCTION <br /> On behalf of Forward Inc. (Forward), this report presents water quality monitoring data <br /> generated during the first quarter 2017 monitoring period for the Forward Landfill in San <br /> Joaquin County, California. Monitoring was performed in accordance with requirements listed <br /> in the Central Valley Regional Water Quality Control Board (RWQCB) Order No. 115-2014-0006. <br /> For reporting purposes, the water quality monitoring network consists of two units: the <br /> Forward Unit and the Austin Unit. Section 1 provides a description of the monitoring network, <br /> site inspections, and standard observations; Sections 2 and 3 include discussions of water <br /> quality data for the Forward and Austin Units, respectively. <br /> 1.1 Monitoring Network <br /> The water quality monitoring network at the Forward Unit currently includes 15 groundwater <br /> monitoring wells (five of which are dual depth well pairs), one domestic well, two surface water <br /> monitoring stations, and 10 lysimeters (Figure 1-1). Monitoring wells at the Forward Unit have <br /> been constructed to monitor groundwater at the facility as follows: <br /> FORWARD UNIT GROUNDWATER MONITORING NETWORK <br /> MONITORING POINT MONITORING POINT I.D. <br /> Groundwater Monitoring MW-22,MW-23R, MW-24 <br /> Wells—Background <br /> Groundwater Monitoring MW-1A/13, MW-2A/B, MW-3A/B, MW-10, MW-13A/B,MW-14A/13, <br /> Wells—Compliance MW-15,MW-16, MW-17, MW-18,MW-19, MW-21 <br /> Domestic Well DW-9690 <br /> Piezometers* MW-113, MW-213, MW-313, MW-1313, MW-14B <br /> Surface Water Stations FSW-1, FSW-2 <br /> Lysimeters E-1, E-2,W-1,W-2, LY-A, LY-BG1, D-93A,WMW-D-01N, <br /> WMW-D-01S,WMW-D-02 <br /> Note: *-Piezometers are sampled in the event that the"A"well in the dual depth well pairs is dry. <br /> As presented on the following table, the monitoring network at the Austin Unit currently <br /> includes 33 groundwater monitoring wells, two domestic wells, two surface water monitoring <br /> stations, and seven lysimeters (Figure 1-1). The detection monitoring program (DMP) wells are <br /> used to detect for a potential release from the landfill, while the corrective action program <br /> (CAP) wells are used to evaluate changes in water quality and the effectiveness of the <br /> corrective action measures. Of note, the 19 evaluation monitoring program (EMP) wells were <br /> constructed as part of an on-going investigation. <br /> Project No.5017.1030 I Water Quality Monitoring Report 1 <br /> April 2017 <br />