C <br />IV. GROUND -WATER SAMPLING AND ANALYSIS PLAN <br />The sampling and analysis procedures for the proposed ground -water <br />monitoring system are described below. The procedures are provided so <br />that consistent and reproducible methods are used to obtain samples <br />from monitoring wells and that proper analyses are performed on the <br />samples. <br />A. MONITORING PARAMETERS <br />To establish baseline ground -water quality data for the site, EMCON <br />analyzed ground -water samples from Wells G-1 and G-2 for the following <br />parameters: <br />• Volatile organic compounds, <br />according to EPA Method 624 <br />• Semivolatile organic <br />compounds, according to EPA <br />Method 625 <br />• Pesticides and polychlorinated <br />biphenyls, according to EPA <br />Method 608 <br />• Zinc <br />• Phenols <br />• Alkalinity <br />• 27 ICRP metals <br />• Total organic <br />carbon <br />• Chloride <br />• Nitrate <br />• Iron <br />• Notal dissolved <br />solids <br />• Electrical <br />conductivity <br />• Total Kjeldahl <br />nitrogen <br />A discussion of the analytical results is contained in an EMCON <br />Associates report (1987b). Based on the results of the baseline moni- <br />toring program and until such time as waste acceptance is initiated at <br />the site, the following routine annual sampling and analytical program <br />is recommended for Wells G-1, G-2, and G-3 (when installed): <br />• pH <br />• Electrical conductivity <br />PJ9 9390207.00D <br />14 <br />• Chloride <br />• Nitrate <br />