• Exhibit 5 Page 3 of 4 <br />Bid No. 4362 <br />Paye 6 <br />INDICATE IN THIS COLUMN <br />THE EXACT SPECIFICATIONS <br />OF THE EQUIPM;,.NT BIS ORANY VARIATIONS FROM <br />THESE SPECIFICATIONS <br />° Static ground connection. <br />Flame arrested lower air vents <br />' Roof vents to have security bars to <br />prevent unauthorized entry and bird <br />screens. same <br />° Fork lift pads, mounted under floor <br />^an. To permi. li`.in� <br />f _ �' _nom either <br />the front. or rear of the locker. <br />CHEMICAL RESISTANCE TESTS: <br />Spot resistance after 48 hours of contact. <br />or exceed the following tests: Lockers bid must meet <br />Orcanic Acids: - Acetic (5X & ,-0%). Oleic - No <br />ge <br />Lactic - Slight softening after C48nhours. <br />Mineral Acids: - Hydrochloric (5X), Sulphuric (5X & 25X), <br />Phosphoric (10X) - No Change <br />Oxidizing Agents: - Nitric Acid (5X), Hydrogen Peroxide (30) <br />No Change. Household Bleach (6% <br />Hydrochlorite Soln.). Saturated chlorine <br />water. Chromic Acid (20X) - May cause <br />some discoloratior. after 24 - 48 hours. <br />Solvents: - Mineral Sprits, Xylol, Ethyl Alcohol, <br />Trichloroethylene, Methyl Ethyl Ketone, <br />Skydrel 500, Premium Gasoline - No Change <br />Salt Solutions: - Sodium Chloride (5X & 30%) <br />Copper Chloride (20X) - No Change. <br />Grease & Oils: - Mineral Oil, Sour Crude Oil, Vegetable Oil <br />No Change. <br />DielectricStrenct. ASTM D - 149 - 59 - Primer 5251/5252 - <br />800 volts, -Lt. Gray 5243/5242 - 1600 volts <br />White 5240/5242 - 2000 Volts. <br />