i <br /> i. Leachate quantities do not indicate significant intrusion of water, or difficulty in meeting regulatory <br /> limits. <br /> Normal operation of the leachate system at the North County Landfill provides redundancy in <br /> absorption. Leachate may be pumped to the deep infusion points,to a leachate storage tank, to the <br /> active landfill face if the active face is over Area 3, 4, or other future lined Areas. <br /> Facilities <br /> The leachate facilities for each Area include: <br /> ■ Sump with dedicated leachate pump. <br /> ■ Volumetric flow meter for the sump pump, indicating total gallons pumped(the meter for Area 4 <br /> also indicates instantaneous flow rate). <br /> ■ A leachate storage tanks. These tanks are normally not in use but are available if leachate cannot <br /> be returned to the refuse directly from the sump. <br /> o Areas 1 and 3 sumps share one tank(3,000 gallons) <br /> o Area 4 is provided with a separate tank(12,000 gallons). <br /> ■ Float switches within each leachate tank activate alarms based on high or low level conditions. <br /> o Under high-level conditions,the leachate sump pump are deactivated. This prevents <br /> overflow of the tanks. <br /> o Under low-level conditions,pumps that can remove leachate from the tanks are <br /> deactivated,preventing the operation of these pumps with insufficient fluid. <br /> ■ Transfer pumps at each leachate tank which can deliver leachate into a water truck if needed. <br /> ■ Return pump at Area 4 leachate tank to deliver leachate to a location other than a water truck, if <br /> needed. Although not yet needed, this pump would be used to deliver leachate to a Area with a <br /> Subtitle D-approved liner. <br /> Semi-permanent points of return of leachate to the refuse include three Deep Infusion Points ("dry" <br /> wells), all installed over Lined Area 3. The highest elevation of the base of Area 3 in this area is <br /> approximately 96 NGVD. The bottom of these Deep Infusion Points (DIPs) are approximately at <br /> elevation 140 ft NGVD. Approximately 50 feet of refuse in multiple lifts exists between the point of <br /> infusion and the base of the landfill. Construction and alteration of the DIPs was reported in detail in the <br /> First Semester 2005 Groundwater and Surface Water Monitoring Report. Leachate was not returned to <br /> DIPs in this monitoring period. <br /> Additional infusion areas have been constructed in Area 4 as needed to accept leachate. <br /> Normal Operation <br /> Leachate drains by gravity to the Area sumps from which it is pumped directly to the landfill refuse per <br /> the WDRs. The sump pump operates automatically, based on leachate levels within the sump. <br /> Operation of any Area sump pumps is conditional upon sufficient water in the sump (indicated by the <br /> level sensor on the pump)and available capacity in the associated leachate tank(indicated by the float <br /> switch in the tank). <br /> Control points for the pumps are: <br /> North County RC&SL Public Works/Solid Waste <br /> 1"Semiannual 2014 Groundwater Monitoring 9 County of San Joaquin—July 31,2014 <br />