My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_1988_2
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CORRAL HOLLOW
>
31130
>
4400 - Solid Waste Program
>
PR0440003
>
Archived Reports
>
ARCHIVED REPORTS_1988_2
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2020 3:52:44 PM
Creation date
7/3/2020 11:04:07 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
1988_2
RECORD_ID
PR0440003
PE
4434
FACILITY_ID
FA0003698
FACILITY_NAME
CORRAL HOLLOW LANDFILL
STREET_NUMBER
31130
STREET_NAME
CORRAL HOLLOW
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
25303010
CURRENT_STATUS
01
SITE_LOCATION
31130 CORRAL HOLLOW RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4434_PR0440003_31130 CORRAL HOLLOW_1988_2.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
278
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Method 102 Revision 1 <br />the concentration of a secondary working standard. <br />7.3.1.2 Any secondary standards prepared from the reference <br />standard must show the same response factor as the <br />original reference standard. Intercomparisons are <br />made on a monthly basis. <br />7.3.1.3 A working standard, prepared by diluting an NBS <br />0 reference material of about 10 ppm to about 10 ppb, <br />is generally used for daily calibrations. <br />7.3.1.4 The stability of working standards must be such that <br />there is less than a 10% change in thirty days. <br />7.3.1.5 There shall be at least one working standard whose <br />concentration lies within the interval of 5 to 20 ppb. <br />7.3.1.6 A second working standard of a higher concentration <br />shall be prepared for use in two point calibrations. <br />7.3.1.7 A quality assurance audit of the standards is prepared <br />annually. <br />7.3.2 Calibrations are performed on a daily schedule. <br />7.3.2.1 The daily calibration consists of at least two calibra- <br />tion points bracketing the anticipated sample con- <br />centrations. <br />7.3.2.2 The calibration is repeated if either the slope or the <br />response at the limit of detection (LOD) of the fitted <br />line changes by more than 5%. If the calibration fails <br />on both runs, an NBS 0.25 ppm reference standard is <br />used to validate the calibration. <br />7.3.2.3 If the lamp voltage is adjusted, allow time for the <br />lamp to stabilize and repeat the calibration. <br />7.3.2.4 A record is kept of the lamp voltage settings and all <br />preventative maintenance procedures i.e. lamp replace- <br />ments, cleaning of lamp windows. <br />7.3.2.5 Blank samples are run daily between calibrations and <br />sample analyses as necessary. <br />7.3.2.6 A single point span calibration may be substituted for <br />the two point calibration procedure for a maximum of <br />four consecutive days provided the response factor <br />does not change by more than 10% during the time <br />interval.. <br />Linearity is a fac-tol- that is checked periodically. <br />7.3.3.1 A gas chromatographic linearity check is performed <br />annually with standards of at least 4 different con - <br />6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.