Laserfiche WebLink
C <br />r <br />Show the locations of test borings on the plan. <br />Describe surface and cover soils using the Unified Soils <br />Classification system (USCS). .Test borings must extend <br />at least 5 feet below the depth of the proposed disposal <br />areas. Soils, geology, and groundwater data must be <br />provided by qualified staff or consultants.. <br />90) Description of all surface and subsurface drains which are <br />to be used to control water from areas on, or adjacent to <br />the disposal site. The location and type of protective <br />dikes, berms, and levees shall be described. <br />The locations of primary drains, berms, etc., should be <br />shown on the plan. The design basis of drainage <br />control devices is to be given; this may require the <br />determination of typical runoff coefficients and runoff <br />volumes for 100 year flood conditions. <br />99} If leachate generation is anticipated, describe the method <br />of monitoring, collection, treatment, and necessary <br />disposal. <br />If leachate barriers are proposed, describe their <br />length, width, depths, and design characteristics. <br />Show the locations on the plan. Describe monitoring <br />and sampling procedures. Indicate whether barriers are <br />in place or to be installed. Estimate the volume of <br />leachate to be handled and the manner of removal from <br />the control barrier system (periodic pumping, etc.). <br />Indicate the manner of treatment and point of discharge <br />of treated leachate. <br />