Laserfiche WebLink
Six VOCs were reported this quarter, four above the laboratory's practical quantification limit <br /> (PQL) and one below the PQL at"trace" concentrations (Table 1). <br /> Trend analysis of VOC concentrations indicate increasing trends for 1,1-Dichloroethane, <br /> Dichlorodifluoromethane, PCE and Freon 11. Trend analysis also indicated a decreasing trend in <br /> Cis 1,2-Dichlroethene, and TCE this quarter. Trend analysis will continue to be used quarterly to <br /> evaluate concentrations of VOCs in MW-8. <br /> Methylene Chloride ,1 previously repeatedly reported at this well, has not been detected since May <br /> 2012. This indicates improving groundwater quality at this well. <br /> AI-W-9A (Newly-installed): <br /> This is the eighth quarter in which MW-9A and the other off-site wells were monitored. <br /> Concentrations of all parameters were within established concentration limits where the limits <br /> could be determined (Table 1). <br /> Six BTEX VOCs were reported in the first sampling event this quarter however,these compounds <br /> were not detected in confirmation sampling collected on February 19, 2014. Therefore, the <br /> "detections" of the initial sampling event were due to lab error and do not indicate groundwater <br /> impact. . <br /> With the exception of false positives,No VOCs were reported in MW-9A this quarter(Table 1). <br /> Data is not sufficient to establish a trend in this well. <br /> -10A (Newly-installed,Apparently No Longer Impacted): <br /> Concentrations of all parameters were within established concentration limits where the limits <br /> could be determined (Table 1). <br /> Six BTEX VOCs were in the first sampling event reported this quarter;however,these compounds <br /> were not detected in confirmation samples collected on February 19, 2014. Therefore,the <br /> "detections" of the initial sampling event were due to lab error and do not indicate groundwater <br /> impact. <br /> With the exception of false positives,No VOCs were reported in MW-l0A this quarter(Table 1). <br /> Data is not sufficient to establish a trend in this well. <br /> 3fW IIA (Newly-installed, Apparently No Longer Impacted): <br /> 1 Concentrations of all parameters were within established concentration limits where the limits <br /> could be determined (Table 1). <br /> Two BTEX VOCs were reported in the first sampling event this quarter; however,these <br /> compounds were not detected in confirmation samples collected on February 19, 2014. Therefore, <br /> the "detections" of the initial sampling event were due to lab error and do not indicate <br /> groundwater impact. <br /> Corral Hollow Sanitary Landfill 14 Department of Public Works/Solid Waste <br /> Is'Quarter 2014 Groundwater Monitoring County of San Joaquin—March 15,2014 <br />