Laserfiche WebLink
A"significantly increasing"trend is reported by the Sanitas program for EC, and TDS thisq uarter <br /> (Table 3). <br /> No VOCs were reported at this well this quarter. Other than false positives,no VOCs have been <br /> reported since Toluene was reported in 2005 when the well was first installed. These Toluene data <br /> indicate that this compound was probably introduced when this well was installed in 2003,but <br /> quickly reduced to "trace"in three quarters. Excluding probable contamination during well <br /> construction and compounds also found the QC blanks, no VOC has been reported in this well. <br /> Therefore,there has been no indication of impact from the landfill at this well. <br /> MW-7(Up gradient): <br /> Concentrations of all parameters were within established concentration limits where the limits <br /> could be determined (Table 2). <br /> No VOCs were reported at this well this quarter. VOCs were last detected in this well on <br /> April 23, 2004. These detections are believed to have been introduced during well construction, <br /> and do not indicate groundwater impact from the landfill. <br /> Surface water <br /> Surface water samples were not available during staff site visits this quarter due to lack of rain. <br /> Such samples were last collected on January 27, 2011. All concentrations of field parameters and <br /> constituents of concern were below established concentration limits where the limits could be <br /> determined. An upcoming revision of the Stormwater Pollution Prevention Plan will identify the <br /> Corral Hollow Landfill as a"non-discharge" site, after which upstream and downstream samples <br /> will no longer be taken from the Corral Hollow Creek. <br /> Unsaturated Zone Soil Pore Gas <br /> The Monitoring and Reporting program for the landfill requires semi-annual VOC testing by <br /> TO-15 analysis. Soil gas samples were collected on April 25, 2014, and are included in this <br /> report. The concentrations of major gasses recorded during this TO-15 sampling event are also <br /> included. <br /> Before sampling,the concentration of major gasses (Methane, Carbon Dioxide, and Oxygen) and <br /> pressure were measured using a CES-LANDTEC GEMTm2000 portable gas detector. The <br /> GEMTm2000 was operated until a steady-state gas composition indicated that the well was purged <br /> and ready for sampling. Soil gas samples were collected in 1-liter Summa canisters and sent for <br /> VOC analysis by EPA method TO-15. VOCs were detected in all ten soil gas samples as shown <br /> on Table 4. <br /> Corral Hollow Sanitary Landfill 17 Department of Public Works/Solid Waste <br /> 2nd Quarter 2014 Groundwater Monitoring County of San Joaquin—July 15,2014 <br />