My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2000-2011
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MANTHEY
>
0
>
4400 - Solid Waste Program
>
PR0440006
>
COMPLIANCE INFO_2000-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/17/2021 11:34:41 AM
Creation date
7/3/2020 11:06:46 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2000-2011
RECORD_ID
PR0440006
PE
4434
FACILITY_ID
FA0004515
FACILITY_NAME
FRENCH CAMP LANDFILL
STREET_NUMBER
0
STREET_NAME
MANTHEY
STREET_TYPE
RD
City
STOCKTON
Zip
95231
APN
16307035
CURRENT_STATUS
02
SITE_LOCATION
MANTHEY RD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\sfrench
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4434_PR0440006_0 MANTHEY_2000-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
359
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITORING AND REPORTING PROGRAM NO. 6 <br /> FORWARD INC. <br /> ALLIED WASTE INC. <br /> FOR CLOSURE OF <br /> FRENCH CAMP MUNICIPAL SOLID WASTE LANDFILL <br /> SAN JOAQUIN COUNTY <br /> The Discharger shall determine the groundwater flow rate and direction in the <br /> uppermost aquifer and in any zones of perched water and in any additional zone of <br /> saturation monitored pursuant to this Monitoring and Reporting Program, <br /> quarterly, including the times of highest and lowest elevations of the water levels <br /> in the wells. Quarterly water levels potentiometric surface maps will be reported <br /> in the detection monitoring report. <br /> Hydrographs of each well shall be submitted showing the elevation of <br /> groundwater with respect to the elevations of the top and bottom of the screened <br /> interval and the elevation of the pump intake. Hydrographs of each well shall be <br /> prepared quarterly and submitted annually. <br /> Groundwater samples shall be collected from the point-of-compliance wells, <br /> background wells, and any additional wells added as part of the approved <br /> groundwater monitoring system. Samples shall be collected quarterly for one year <br /> after completion of closure construction and semi-annually there after. Samples <br /> will be analyzed for the monitoring parameters in accordance with the methods <br /> specified in Table I. <br /> The monitoring parameters shall also be evaluated each reporting period with <br /> regards to the cation/anion balance, and the results shall be graphically presented <br /> using a Stiff diagram, a Piper graph, or a Schueller plot. Samples for the <br /> constituents of concern specified in Table I shall be collected and analyzed in <br /> accordance with the methods listed in Table VI every five years. <br /> 2. Landfill Gas Monitoring <br /> The Discharger shall operate and maintain a landfill gas detection monitoring <br /> system in accordance with a detection monitoring plan approved by the Executive <br /> Officer. The Discharger shall collect,preserve, and transport samples in <br /> accordance with the quality assurance/quality control standards contained in the <br /> approved Sample Collection and Analysis Plan. <br /> Landfill gas samples shall be collected from the monitoring devices and <br /> background monitoring devices of the approved monitoring system. The collected <br /> samples shall be analyzed for the listed constituents in accordance with the <br /> methods specified in Table II. Landfill gas samples shall be collected quarterly <br /> for one year after completion of closure construction and semi-annually thereafter. <br /> All monitoring parameters shall be graphed so as to show historical trends at each <br /> monitoring point. <br />
The URL can be used to link to this page
Your browser does not support the video tag.