Laserfiche WebLink
2 <br />CalRecycle <br />Closed Disposal Site Inspection Report (188) <br />THE ABOVE FACILITY WAS INSPECTED FOR COMPLIANCE WITH APPLICABLE SECTIONS OF THE DNISION W OF THE PUBLIC RESOURCES CODE (PRC) AND TITLE 14 AND TITLE 27 CALIFORNIA CODE OF REGULATIONS (CCR) I <br />I x 121150 - Drainage and Erosion Control I <br />Comments: Drainage at the west and northwest sides of the primary site and at the north side of the secondary <br />site did not appear to function as intended. New erosion channels were observed at the southeast side of the <br />primary site. Continuation of AC from the last inspection. <br />a. Provide adequate drainage of runoff for the entire site. <br />b. Make necessary repairs of erosion channels and take measures to prevent future waste <br />Notes: <br />A. The landfill gas extraction flare was operating at time of inspection. <br />B. Burrow holes observed at the northwest side of the secondary site and southeast side of the primary site. Make <br />necessary repairs of burrow holes and take measures to prevent further burrowing. <br />C. The fence along the east perimeter needs repair. <br />D. Concentrations of gas probe measured the following for methane%: GW3=0 (all three probes), GW6=0 (all three <br />probes), GW7=0 (all three probes), GW4 Shallow =0, Intermediate =1.3, Deep = 1.5. <br />E. Previous AC's cleared. <br />